Mod:
BMIV15/R2
Production code:
19046413
1
2
/
201
7
Page 1: ...Mod BMIV15 R2 Production code 19046413 12 2017 ...
Page 2: ...INSTRUCTIONS MANUAL REFRIGERATED TABLES Profi Line Cod 12170202 ...
Page 3: ...2 Special maintenance 21 INSTALLATION USAGE AND MAINTENANCE MANUAL Before starting the table up we would like to thank you for the confidence you have placed in us on purchasing this refrigerated table and recommend you read and follow the steps detailed in the instructions This manual is designed to offer the information necessary for the installation start up and maintenance of the refrigerated ...
Page 4: ...ONNECTION Before connecting the refrigerated table to the socket check that the network voltage and frequency correspond with those indicated in the appliance s nameplate It is essential that the electrical installation where the table is going to be connected has an EARTHING SOCKET in addition to the appropriate protection of the magneto thermal switch and differential we recommend 30 mA Check th...
Page 5: ...ENT CONSUMP GENERAL DIFFEERENCIAL VOLTAGE A W FUSTE T DEVICE MR2 R2 BMIV15 R2 230v 50Hz 1 6 261 2 A 30 mA MR3 R2 BMIV20 R2 230v 50Hz 1 6 261 2 A 30 mA MR4 R2 230v 50Hz 2 3 405 4 A 30 mA NUMBER DESCRIPTION 1 MODEL 2 SERIES NO 3 REFRIGERATION POWER WATTS 4 WORKING VOLTAGE 5 FREQUENCY 6 CURRENT INTENSITY 7 TYPE OF COOLANT GAS 8 GRAMS OF COOLANT GAS 9 CLIMATIC CLASS N 4 ó T 5 10 STANDARD 11 PCA MODEL ...
Page 6: ...ight The manufacturer is not responsible for any operation not mentioned in this manual having to be followed the next recommendations and warnings WARNING The appliance contains in the refrigerant circuit propane R290 or isobutane R600a a highly environmentally compatible natural gas that is inflammable While transporting and installing the appliance ensure that no parts of the refrigerant circui...
Page 7: ...oid opening the doors insofar as it is possible to prevent the temperature from rising If the interruption is over 20 minutes you must make sure that the food does not exceed the critical points and watch that it is not affected and prevent opening the doors The minimum temperatures so that the food does not start to deteriorate are 2 2 PRECAUTIONS 1 Stability is guaranteed even with the doors ope...
Page 8: ...used by something simple that user themselves can solve The following are examples a The refrigerator does not work Check that electricity reaches the refrigerator by checking if the power switch is on b Temperature too high Check that there are no heat sources nearby Check that the thermostat s cut off is at a value near to 0ºC to do so press the set key on your thermostat once and release it Che...
Page 9: ...ned the appliance off Take all the necessary precautions before accessing the area of the condenser unit given the existence of high temperatures of some components with the resulting risk of burns If the flexible power cable or cord is damaged it must be replaced by the manufacturer after sales service or authorised technical personnel in order to prevent risks It if is replaced the earth pin mus...