Dialogic
®
4000 Media Gateway Series Integration Note
35
Configure the form as follows:
Note: Parameters not listed below can be left at their default settings.
•
Select as Circuit number
1
, and as Cabinet number, Shelf number, and Slot number the number in which the
T1 QSIG line is being installed.
•
Set
Trunk Num
to an unused trunk number that has at least 22 unused trunk numbers available after it
(e.g., if you select 100, 101-122 must also be available).
•
Set
Trunk Service Number
to the trunk service number defined in Step 9 of SX-2000 Light
Administration.
•
Set
Circuit Desc. Number
to the circuit descriptor number defined in Step 8 of the SX-2000 Light
Administration.
•
Set
Interconnect Number
to a valid interconnect number.
•
Press
[ESC] then [2] to define the range programming, a
RANGE PROGRAMMING Parameters
data entry
field will appear in the main screen.
•
Set
Trunk Num
to the trunk number defined earlier in this step, and press [TAB].
•
Set
the
Trunk Service Number
to
0
, and press [TAB].
•
Set
Circuit Desc. Number
to
0
, and press [TAB].
•
Set
Interconnect Number
to
0
, and press [TAB].
•
Set
Comp Zone IO
to
0
, and press [TAB].
•
Set
Tenant Number
to
0
, and press [TAB].
•
Press
[ESC] then [2] to define the range programming, a
Specify number of lines
data entry field will
appear in the main screen.
•
Set
Specify number of lines
to
22
and press [ENTER]
•
Press
[ESC] then [4] to execute the command.