Dialogic PCI Linecard Installation and Replacement

 

R3B

 

ã

 

Aug 2001 Ericsson Enterprise AB

 

5

CTbus connector

JP6 

JP7 

Slot retainer 

bracket

SW1 SW2 

Table 3: D/240PCI-T1 technical specifications 

 

Feature Specification 

Channelization (channel 
order) 

1–24; the correlation between channelization and OneBox 
ports is determined by the card’s linecard identification number 

Dialing 

DTMF 

FCC registration number 

EBZUSA-20078-XD-N 

Framing type 

D4, also known as Superframe (SF) 

Digital network interface 

On board DSX-1 interface 

Line coding (receiver) 

AMI 

Line coding (transmitter) 

AMI 

Other equipment 

CSU—required 
DSU—depends on capabilities of CSU; usually not required 
CSU–to–D/240PCI-T1 cable—must have an RJ-48C 
connector to connect to the D/240PCI-T1 

Ringer equivalence number 

0.0A 

Supervisory signal 

2- or 4-wire E&M—wink-start E&M signaling is the default and 
recommended protocol; immediate-start E&M requires manual 
configuration  
FXS—immediate-start FXS signaling requires manual 
configuration 

T-1 signaling 

Robbed bit 

T-1 span support 

Full 24 timeslots (partial and fractional T-1 are not supported) 

Timing (synchronization) 

Loop timing (external clock) 

Voice coding 

PCM 

 
 

 
 

Figure 3. Layout of the D/240PCI-T1 

Summary of Contents for D/120JCT-LS

Page 1: ...o install Dialogic System Software versions 2 3 3 and SR5 01 The information in this document pertains to platforms running version 1 1 or later of OneBox We recommend that you read this entire docume...

Page 2: ...and from your body Turn off and unplug your computer before removing the case Gathering Tools and Equipment Before you begin disassembling the OneBox platform verify that you have the following requir...

Page 3: ...me of these specifications For example in the United States some telephone companies require an FCC registration number if the linecard is connected directly to central office CO lines Contact your lo...

Page 4: ...cification Number of ports 1 12 the OneBox port assignment is determined by the card s linecard identification number Dialing DTMF FCC registration number EBZUSA 34827 KX N Analog network interface On...

Page 5: ...DSX 1 interface Line coding receiver AMI Line coding transmitter AMI Other equipment CSU required DSU depends on capabilities of CSU usually not required CSU to D 240PCI T1 cable must have an RJ 48C...

Page 6: ...wo or more linecards installed in the platform are configured to use the same linecard identification number the Dialogic System Software device driver will be unable to locate either linecard Unique...

Page 7: ...eme for PCI linecards called Geographic Sequencing by Dialogic To set the linecard identification number Dial the rotary switch to select a unique linecard identification number as shown in the exampl...

Page 8: ...I T1 linecards use hardware to configure the CTbus D 120JCT LS linecards are configured automtically by the Dialogic System Software Skip to Configuring the Default Line State Hook Switch State To con...

Page 9: ...If the switch is in the OFF position the default line state is onhook callers will get a ring no answer RNA response If the switch is in the ON position the default line state is offhook callers will...

Page 10: ...gure 1 Figure 2 or Figure 3 for the location of the slot retainer bracket To remove the slot retainer bracket Choose one If the platform is designed for Then PCI cards only Remove the slot retainer br...

Page 11: ...all of those linecards must share IRQ 5 After you have prepared the Dialogic PCI linecards for installation and have determined how to assign IRQs to the expansion slots they will use you can install...

Page 12: ...ot for the replacement linecard Adds ports to the OneBox platform Select an empty PCI expansion bus slot that will be assigned IRQ 5 and remove its retaining screw and cover plate 9 Insert the linecar...

Page 13: ...e connector does not seat fully on the card turn the cable around and try again When attached correctly the colored stripe on the cable faces the rear bracket The stripe must be adjacent to pin 1 on t...

Page 14: ...atform to the telephone system As described in Assigning the Linecard Identification Number OneBox assigns port numbers in ascending order based on the linecard identification number For example a D 4...

Page 15: ...11 single channel connectors at the back of the D 41EPCI to a two channel RJ 14 linecord If linecord adapters are required and not included with the linecards please contact your technical service rep...

Page 16: ...identification number For example a D 120JCT LS linecard to which you assigned the linecard ID 1 will be assigned line numbers 1 12 a D 120JCT LS linecard to which you assigned the linecard ID 2 will...

Page 17: ...etwork uses you may need linecord adapters to connect the computer platform to the telephone system switch If linecord adapters are required and not included with the linecards please contact your tec...

Page 18: ...1 24 a D 240PCI T1 linecard to which you assigned linecard ID 2 will be assigned line numbers 25 48 as shown in Figure 11 Keep this line number assignment scheme in mind when connecting each D 240PCI...

Page 19: ...tomer premise equipment monitors the T 1 line for violations and generates keep alive signals and error condition messages A keep alive signal is a bit stream of all ones used to power repeaters in th...

Page 20: ...1 lines that carry a voltage to power regenerative repeaters are called wet T 1 This voltage traditionally has also been used to power the CSU at a site Since 1987 the Federal Communications Commissio...

Page 21: ...ou are connecting to the D 240PCI T1 This will provide adequate grounding to the platform chassis when the cable is attached to a properly installed D 240PCI T1 card Figure 13 Pinouts for RJ 45 48C co...

Page 22: ...for Windows NT 1 0 and 1 10 DNA 2 On OneBox CD ROM OneBox 2 0 DNA 3 3 On OneBox CD ROM OneBox 2 01 SR5 01 On separate CD ROM provided with OneBox server Removing Existing System Software Before instal...

Page 23: ...ams point to Dialogic System Software and select Uninstall 6 At the Uninstall dialog box click Yes IMPORTANT If the uninstall program displays a warning about deleting the shared file Ctl3d32 dll clic...

Page 24: ...lacement R3B Aug 2001 Ericsson Enterprise AB 24 10 From the C Program Files directory delete the Dialogic folder and its contents 11 Restart the computer 12 Continue to the following section Installin...

Page 25: ...rvice Pack 1 for DNA Version 3 3 D 120JCT LS Only later in this document Also Windows NT 4 0 with Service Pack 6A must be installed on the telephony server prior to installing Dialogic System Software...

Page 26: ...s dialog box click Custom 9 In the Custom Components Selection dialog box select only the Dialogic Drivers Firmware Configuration Files option then click Next 10 In the Destination Location dialog box...

Page 27: ...ar in the Current Settings list If you need to change any of the options return to the appropriate dialog box by clicking Back otherwise click Next 12 In the Please Make Your Selection Now dialog box...

Page 28: ...want to restart my computer now then click OK 14 Choose one If you have installed Dialogic System Software Then DNA 3 3 and are using a D 120JCT LS linecard Proceed to Installing Service Pack 1 for D...

Page 29: ...for DNA version 3 3 1 Make sure that the telephony server is stopped and that none of its administrative utilities are running 2 Insert the Service Pack 1 CD ROM into the CD ROM drive of the server pl...

Page 30: ...hange the configuration data for any of the linecards in the Configured Devices list The configuration of the Dialogic System Software can only be changed when the Dialogic system service is stopped C...

Page 31: ...Stop icon in the toolbar 4 Highlight one of the cards that appears in the Configured Devices list Note If the card you added does not appear in the Configured Devices list refer to the section Adding...

Page 32: ...System tab and verify that the three parameters are set appropriately for the card you are configuring If so skip to step 12 otherwise continue with the following step 6 From the Parameter list selec...

Page 33: ...e Parameter list select PciSlotNumber 9 From the Value list select the number of the PCI slot in which the card is installed 10 From the Parameter list select PciBusNumber 11 From the Value list selec...

Page 34: ...hemes used around the world Law and A Law Telephone switches in North America and Japan typically use Law Telephone switches in South America and Europe typically use A Law 13 From the Value list sele...

Page 35: ...ntry Note The Country tab allows you to configure the Dialogic linecards installed in the platform for use in specific countries Based on the value selected for the Country parameter the DCM will sugg...

Page 36: ...m the Parameter list select Frequency Resolution if available 17 From the Value list select FREQRES_HIGH 18 Click Apply then OK to apply the changes you have made 19 Repeat steps 4 through 18 for each...

Page 37: ...ck the green Start button on the toolbar 21 From the Service menu point to Startup Mode then select Automatic 22 Click Close at the confirmation dialog box 23 Close the DCM 24 Start OneBox and check t...

Page 38: ...ls to automatically detect a linecard that was added to the platform you can add the linecard manually with the DCM To add a linecard 1 From the Start menu point to Programs point to Dialogic System S...

Page 39: ...01 Ericsson Enterprise AB 39 3 From the Action menu select Add Device 4 Follow the DCM Add Hardware Wizard s on screen instructions to add the board and refer to the section Configuring Dialogic PCI L...

Page 40: ...e uses To configure the line type 1 Log on to Windows NT Server with an account that has local Administrator privileges on the OneBox platform 2 From the Start menu point to Settings and select Contro...

Page 41: ...FXO signaling Wink start or immediate start In OneBox E M signaling defaults to wink start and FXS signaling defaults to immediate start OneBox defaults to E M signaling and must be changed to FXS si...

Page 42: ...variable by entering the appropriate text in the Value box as shown in the example below If protocol you want the D 240PCI T1 to use is Then E M In the Value box type PBXINFO T1EANDM PRO FXS FXO In th...

Page 43: ...an account that has local Administrator privileges on the OneBox platform 2 Shut down OneBox 3 Start Notepad or the text editor of your choice 4 In the D Cx Bin Pbxinfo folder open the file you want...

Page 44: ...t mode used by the signaling protocol is Then Wink and you want to use immediate Modify the Start Wink line to Start Immediate Immediate and you want to use wink Modify the Start Immediate line to Sta...

Page 45: ...g a loopback plug into the RJ 48C connector of the D 240PCI T1 refer to The Loopback Plug for additional information 3 Switch the loopback test switch SW500 to the Off or Loopback Mode position refer...

Page 46: ...pback mode as shown in Figure 16 Loopback mode enables you to verify the T 1 connection The switch overrides any board modes set by the Dialogic System Software The Remote Loopback Test Indicator abov...

Page 47: ...ests specified by the manufacturer You have determined the cause of the problem Repair or replace the CSU contact the manufacturer or vendor for instructions To test the D 240PCI T1 CSU or the CSU D 2...

Page 48: ...Yellow LED Alarm to indicate loss of frame synchronization at the far end of the external network Green and Yellow LEDs May indicate a short in the transmit wire pair the pair connected to the transm...

Page 49: ...is file is created in the D Cx Bin directory as T1ctl log You can the copy this file and send it to Technical Support if requested To start T 1 diagnostic logging 1 Start Notepad or another text edito...

Reviews: