background image

 

 

Page 1 of 2 

Product Profile 

DSP-40S Vehicle Detector 

All this and a 5-Year Warranty too! 

 
             

 

Features 
 

  Works on any in-ground 

inductive loop from 20 to 
2000 microhenries. 

 

  Designed to be cross talk 

free between other loops 

 

  Automatically compensates 

for loop and lead-In sizes 

 

  Separate Power/Fail and 

Detect LED's for both 
channels 

 

  Small profile, perfect for 

many installations 

 

  Fail safe operation 

 

  Wide low-voltage operation 

 

  This series of Diablo 

Controls detectors are 
covered by United States 
Patent number US 
7,132,959 “Non-Interfering 
Vehicle Detection.” 

 

  Separate Power/Fail and 

Detect LEDs. 

Overview 
At last a plug-in detector that will operate on any voltage from 10 
to 30 volts AC or DC. The DSP-40S detector is covered by United 
States  patent  number  US  7,132,959  “Non-Interfering  Vehicle 
Detection.”  This  detector  is  virtually  cross-talk  free  in  most 
applications.  It has been specifically designed to handle parking, 
drive-through  and  access  control  applications  where  solid-state 
outputs  are  required  for  both  the  detect  and  fail  outputs.  The 
sensitivity level may be changed. (See below).  The detector loop 
inductance should be between 20 and 2000 microhenries.  

 

LED Indicators 
The green Power LED will be on steady to indicate the detector is 
operating and powered.  The red Detect LED will turn on when a 
vehicle is over the loop detection area. 

 

Detect Memory 
Power interruptions of short duration are ignored.  If power fails for 
approximately  1  ½  seconds  or  less  the  detector  “remembers”  a 
vehicle.

 

 

Sensitivity and Reset Push Button 
The  Reset/Sens.  button  is  used  for  two  functions.    A  short  press 
and release of the button will reset the detector and the LED's will 
both  flash  from  1  to  4  times,  indicating  the  detector's  sensitivity 
level.  The detector is shipped from the factory with the sensitivity 
set at level 3.

 

 
If a different sensitivity level is required:

 

Push and continue to hold the button until the LED's start flashing 
-  release  the  button  immediately  after  the  desired  number  of 
flashes.  For example, if the sensitivity is to be changed to level 2, 
push  and  hold  the  button  until  the  LED's  flash  twice  then 
immediately  release  the  button.    The  sensitivity  level  can  always 
be  verified  by  a  quick tap on the  push button.   This  will  reset  the 
detector and flash the two LED's indicating the present level.

 

 

Level 1 - Very Low 

 

Level 2 - Low

 

Level 3 - Normal (Factory setting)

 

Level 4 - High

 

 

Loop or Wire Failures 
In  the  case  of  a  loop circuit  failure,  the  green  LED flashes  slowly 
(twice per second) for an open loop circuit failure.  The green LED 
will  flash  fast  (10  times  per  second)  to  indicate  a  shorted  loop 
circuit. 
 