Page 1: ...Flash controller for flashable lights O p e r a t i n g m a n u a l BC 100 20A BC Config ...
Page 2: ...e BC 100 20A for LED lighting 6 5 5 Startup of BC 100 20A with connected LED lighting 7 5 6 Calibration phase 7 6 Flash mode constant current mode 7 6 1 Flash mode 7 6 2 Constant current mode 7 7 Autostart function 7 8 Faults and errors 8 8 1 General 8 8 2 Troubleshooting 8 8 3 Resetting an error fault 8 9 Trigger function 8 9 1 Internal trigger function 8 9 2 External trigger function 8 9 3 Trigg...
Page 3: ... function can be started and stopped with corresponding commands Automatic startup after availability of the supply voltage is also possible In this case no further connection with the interface is necessary The BC 100 20A operates with the saved parameters also after a shut down and re start In addition to the most common use in externally triggered pulse mode the BC 100 20A can also be controlle...
Page 4: ...00 20A to the PC controller via the adapter Start BC Config 3 2 Operation of BC 100 20A First make sure that no LED lighting is connected Connect device to 24 V DC power supply and switch on Make sure that the power supply can deliver pulsed current of at least 6 A if maximum pulsed current is needed 3 3 Login procedure User name user Password di soric Choose the correct Comport and press the OK b...
Page 5: ...and set 4 1 User interface 4 2 Higher level commands Command parameter Explanation Start Check the parameter set for consistency save the configuration if OK enable LED driver Stop Disable LED driver Save Check the parameter set for consistency and save the configuration if OK Logout Disconnect connection ...
Page 6: ...orrect values can result in damage to the connected LED lighting system without warning If all parameters and values are correct and you press the button Save the BC 100 20A will again check the overall configuration for consistency and save it in non volatile memory If the BC 100 20A detects during this check that a combination of parameters values of this configuration is outside of the permissi...
Page 7: ...n of the permissible limits during the calibration procedure the calibration is discontinued and the red LED indicates the error In this case it is necessary to adjust the parameters After successful completion of the calibration phase the BC 100 20A operates with the detected control parameters and the LED driver remains enabled 6 Flash mode constant current mode 6 1 Flash mode In flash mode cont...
Page 8: ...t hardware environment and valid configuration there may be a defect in the BC 100 20A In this case you need to contact the di soric customer service department 9 Trigger function 9 1 Internal trigger function The option intern in the drop down selector Trigger source enables the internal trigger function The BC 100 20A now flashes autonomously with a cycle time that is set via the parameter Cycle...
Page 9: ...In this case the entered value is immediately checked saved and applied if it is within the permissible limits Otherwise the old value is retained unchanged No new calibration phase is necessary 11 Ready output The BC 100 20A is equipped with a ready control output Ready OUT This configurable output is always enabled when the BC 100 20A is ready for the next flash pulse i e when the cycle time has...
Page 10: ...rload and damage The following limit values and restrictions are always checked when the Save and Start commands are executed If they are exceeded an error is output The configuration must then be checked and adjusted 13 2 Limit values in constant current mode Maximum LED lighting current Current 1800 mA 13 3 Limit values in flash mode Duty Cycle Flash current I max TimeOn 1 2000 mA 50000 µs 5000 ...
Page 11: ...9 0 Fax 49 0 7181 9879 179 info di soric com AUSTRIA di soric Austria GmbH Co KG Burg 39 4531 Kematen an der Krems Austria Fon 43 0 7228 72366 Fax 43 0 7228 72366 4 info at di soric com FRANCE di soric SAS 19 Chemin du Vieux Chêne 38240 Meylan France Fon 33 0 476 616590 Fax 33 0 476 616598 info fr di soric com SINGAPORE di soric Pte Ltd 8 Ubi Road 2 07 13 Zervex Singapore 408538 Singapore Fon 65 6...