background image

CLAMP-ON DCA/ACA MULTIMETER ADAPTOR 

                   

     

  OPERATING INSTRUCTION 

 

TABLE OF CONTENTS 

I           

Features

 

II              Panel Description 
III            Specifications 
IV            Operation Instructions 
V              Battery Replacement

 

I. Features: 

 

Plugs into any brand DMM with 400mV or 2V input range for non-contact current monitoring and 
wave form pick- up 

 

1.2” (30mm) clamp jaw opening 

 

Measures DC Current when DMM in DC rang and AC current in to AC range   

 

One touch “Auto Zero” for DCA measurements 

II. Panel Description 

 
 
 
 
 
 
 
 
 

1.  Transformer Jaw 

This is used to pick up current signal. To measure DC/AC current, The jaw must be enclosed. 

2.  Transformer Trigger 

This is used to open the jaw. 

3.  Function Selector Switch 

This is used to select the function user desired, such as DCA, ACA measurement or turn the 
meter OFF. 

4.  Zero Button 

Once this button is pressed, the current reading shall be set to zero. The function is also used 
to  remove  offset  value  caused  by  the  residual  magnetism  remained  in  the  core  for  the  dc 
current measurement. 

5.  Power ON/OFF LED display 
6.  Low Battery LED indication 

When the LED lamp turns on, the battery should be changed. Refer to Section V for battery 
replacement 

7.  Output Terminal – 

This terminal is used as output for DCA - polarity and ACA. (No input) 

8.    Output Te 

This terminal is used as output for DCA + polarity and ACA. (No input) 

9.  Hand Strap   

Put your hand through the hold of hand strap to avoid. 