200A AC MINI  

CLAMP-ON METER

operating manual

Di-Log Test Equipment
28 Wheel Forge Way,  

Trafford Park,

Manchester
M17 1EH, UK

tel: + 44 161 877 0322 

               fax: + 44 161 877 1614

email: [email protected]                 website: www.dilog.co.uk

EN

61010-1

CAT

 

II

600V

Summary of Contents for DL6505

Page 1: ...Maintenance DL6505 200A AC MINI CLAMP ON METER operating manual 1 877 1614 ww dilog co uk EN 61010 1 CAT II 600V ...

Page 2: ...plies with IEC536 class 11 Symbol of conformity confirms conformity with relevant EU directives The meter complies with EMC directives 89 336 EEC Specifically stand ards EN 50081 1 and EN 50082 1 as well as the Low Voltage Directive 73 23 EEC described in the standard EN 61010 1 The meter has been designed in accordance with the safety regulations for electronic measuring instruments EN 61010 1 IE...

Page 3: ...t ensure that the rotary switch is set to the appropriate range Do not turn the rotary switch whilst making a measurement Use the appropriate terminals function and range for your measurements If the value to be measured is not known use the maximum measurement position and reduce the range step by step until a satisfactory reading is obtained Do not use or store the meter in an environment of hig...

Page 4: ...as the low battery indicator appears If the battery is low the meter may give false readings Turn the meter power off when not in use Remove the battery if the meter is in use for a long period Constantly check the battery as it may have leaked A leaking battery will damage the meter The meter may only be opened by a qualified service technician for calibration and repair ...

Page 5: ...mation Features 3 1 2 digit 2000 count LCD display High resolution to 10mA AC Built in non contact AC voltage detector plus flashlight MAX Hold and Data Hold Auto power off 18mm Jaw opening ...

Page 6: ... 5V AAA batteries Low Battery indication BATT displayed on the LCD Auto OFF approx 7 minutes Operating conditions 32 F to 86 F 0 C to 30 C 90 RH 86 F to 104 F 30 C to 40 C 75 RH 104 F to 122 F 40 C to 50 C 45 RH Storage conditions 14 F to 140 F 30 C to 60 C 90 Relative Humidity Altitude Operate at less than 3000 meters Weight 175g including battery Dimensions 164 x 65 x 32mm Jaw opening 18mm Stand...

Page 7: ...ns Specifications 6 2 4 1 5 7 Range Specifications Function Range Resolution Accuracy of reading AC Current 50 60Hz 2A 1mA 80A 200mA 3 0 8 digits Non Contact AC Voltage 100VAC to 600VAC 50 60Hz 3 9 8 ...

Page 8: ...nsor jaw 2 Torch button 3 Rotary function switch 4 Data HOLD key 5 LCD display 6 Clamp trigger 7 MAX HOLD key 8 Non contact AC voltage indicator light 9 Non contact AC voltage detector probe tip Function Maximum Inputs AC Current 200A Input Limits ...

Page 9: ...CA range 2 Press the jaw trigger and clamp around fully enclosing a single conductor Do not allow a gap between the two halves of the jaw Refer to the diagram at right for the correct way to enclose a single conductor 3 Read the ACA value on the LCD wrong correct ...

Page 10: ...de of the electrical outlet 2 If AC voltage is present the detector light will illuminate Note The conductors in electrical cord sets are often twisted For best results rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor Note The detector is designed with high sensitivity Static electricity or other sources of energy may randomly trip the...

Page 11: ...old button The MAX hold button is located on the left side of the meter bottom button The meter reading will not change as readings change rather it will only display the highest reading encountered since the MAX hold button was pressed Press the MAX hold button again to return to normal operation Auto Power Off The auto off feature will turn the meter off after 7 minutes Battery Replacement 1 Whe...

Page 12: ...ment has not been tampered with and returned to us unopened Damage due to dropping abuse or misuse is not covered by the warranty Outside the warranty period we offer a full repair and re calibration service Maintenance WARNING Do not attempt to repair or service your meter unless you are qualified to do so and have the relevant calibration performance test and service information To avoid electri...