19
2.3.4.21 I/O Mode Switch
This register is used to turn I/O Control Mode ON or OFF.
The address is 0x0402. The description of this register is shown in Table 2.24
Table 2.24 I/O Mode Switch
Function
Address
Description
Write
Read
I/O Mode
Switch
0x0402
I/O Control
Switch
0
:
OFF
,
1
:
ON
Current setting
If you have written 1 to this register and have saved all parameters, the gripper will be
initialized automatically after power on.
When the I/O Control Mode is turned on, the gripper can respond to Modbus-RTU commands
and I/O, but I/O has priority.
The control method in different mode is shown in Table 2.252.
Table
2.25 Control method
Switch State
Description
Modbus-RTU
I/O
0
I/O
control
mode off
YES
No
1
I/O
control
mode on
YES
YES
Example:
Set the I/O control mode switch off (write):
Send:
01 06 04 02 00 00 29 3A
Return: 01 06 04 02 00 00 29 3A
2.3.4.22 I/O
Parameter Configuration
Those registers are used to Set the I/O Parameters.
The address is 0x0405-0x0410. The description of this register is shown in Table 2.26.
Table 2.26 I/O Parameter Configuration
Function
High-
byte
Low
bytes
Description
Write
Read
I/O Group 1
0x04
0x05
position 1
0-1000
‰
Current setting
0x06
force 1
20-100 %
0x07
speed 1
1-100 %
NOTE
·
If you just need to control the gripper through Modbus RTU, you should write 0 to this
register and save all parameters to turn off the I/O control mode.