16
Table 2.17 Save Parameter
Function
Address
Description
Write
Read
Save
Parameter
0x0300
Save register
’s
value to Flash
0
:
default
,
1
:
Save all parameters
0
Example:
Save Parameter (Write):
Send:
01 06 03 00 00 01 48 4E
Return:
01 06 03 00 00 01 48 4E
2.3.4.15 Initialization Direction
This register is used to set Initialization Direction of gripper.
The address is 0x0301. The description of this register is shown in Table 2.18.
Table 2.18 Baud Rate
Function
Address
Description
Write
Read
Baud Rate
0x0301
Configure
initialization
direction
0: Open
,
1:Close
(default: 0
)
Current setting
The value of this register is 0 by default.
If the register value is 0, when you send the initialization command, the gripper finger will
open and find the maximum position.
If the register value is 1, when you send the initialization command, the gripper finger will
close and find the minimal position.
Example:
Write 0 to initialization direction register:
Send:
01 06 03 01 00 00 D8 4E
Return:
01 06 03 01 00 00 D8 4E
2.3.4.16 Slave Address
This register is used to set Slave Address of gripper.
The address is 0x0302. The description of this register is shown in Table 2.19.
NOTE
·
The Saving process will take 1-2 seconds, and the gripper won’t response to other
command during this process. The gripper will response this command after saving process
finished.