Tel/Fax: 0755-82734836
www.dh-robotics.com
20
2.3.3.15 Test I/O Parameters
This register is used to test the I/O Parameters.
The address is 0x0400. The description of this register is shown in Table 2.17.
Table 2.17 I/O Control
Function
Address
Description
Write
Read
Test I/O
Parameters
0x0400
Test I/O
Parameters
1
;
2
;
3
;
4
Current setting
This register can be used to directly test 4 groups of I/O parameters through Modbus-RTU to
ensure that the I/O parameters are appropriate. For example, Write 1 to this register, the gripper will
execute action with the first group of I/O parameter.
Example:
Control gripper by using first group of I/O parameter (write):
Send:
01 06 04 00 00 01 49 3A
Return: 01 06 04 00 00 01 49 3A
2.3.3.16 I/O Parameter Configuration
Those registers are used to Set the I/O Parameters.
The address is 0x0405-0x0410. The description of this register is shown in Table 2.20.
Table 2.20 I/O Parameter Configuration
Function
High-
byte
Low
bytes
Description
Write
Read
I/O Group 1
0x04
0x05
position 1
0-1000
‰
Current setting
0x06
force 1
20-100 %
0x07
speed 1
1-100 %
I/O Group 2
0x08
position 2
0-1000
‰
0x09
force 2
20-100 %
0x0A
speed 2
1-100 %
I/O Group 3
0x0B
position 3
0-1000
‰
0x0C
force 3
20-100 %
0x0D
speed 3
1-100 %
I/O Group 4
0x0E
position 4
0-1000
‰
0x0F
force 4
20-100 %
0x10
speed 4
1-100 %
Example:
Set the first group of I/O parameter (write) :