DFM Activor RSI02 Manual Download Page 1

Activor® Remote Control RSI02 (S1890A) Manual            

 

 

 

 

 

 

June 2018

 

General 

RSI02 remote kit comprises one receiver, two pre-learned remotes, a 4-wire harness and a quick mounting 
plate. Through Jumper Setting, It can be set to work with NX/Reliance alarm panels or DSC panel such as 
PC1565(Power632), PC5020(Power864), PC1616/1832/1864 to operate Arm (away/stay), Disarm and Panic 
via the keypad data bus. The receiver is also equipped with two relays that can be used to operate other 
devices such as garage door.   

 

Jumper Setting 

The 4-pin jumper can be found in the upper middle of the receiver.     

-

 

For  NX/Reliance  panel:  ensure  the  2-pin  jumper  cap  remains  to  be  placed  across  pin1  and  2,  as 

-

 

For DSC panel: ensure the 2-pin jumper cap is removed from the socket.   

 

Quick Start and Play 

-

 

For NX/Reliance panel: 

 

Connect 4-wire harness directly to the panel or keypad: Pos Red; Com Black and Data Green 

 Yellow is not 

used.   

-

 

For DSC panel:   

Connect 4-wire harness directly to the panel or keypad, follow colour code then PLUG into the receiver and 
PLAY. The receiver is automatically recognized by the panel 

 no need to use User Code for enrolment.   

 

Receiver layout 

 

 

 

 

 

 

 

Button Operation 

 default setting

 

Button 1:    Press and quick release = Away; press and hold for 3 seconds = Stay 

Button 2:    Disarm from Arm away/stay, or Panic 

Button 3:    Relay 1 output momentary 

Button 4:    Relay 2 output momentary 

Press button 1&2 simultaneously for 3 seconds = Panic 

 

Receiver

 

 