www.dfi .com
14
Chapter 2 Hardware Installation
Chapter 2
eDP Panel Power Select (Optional)
1-2 On: +12V
3-4 On:+5V
5-6 On: +3.3V
(default)
JP19 is used to select the power supplied with the eDP panel.
Important:
Before powering-on the system, make sure that the power settings of JP19 match
the eDP panel’s specification. Selecting the incorrect voltage will seriously damage the
eDP panel.
JP19
2
4
6
1
3
5
2
4
6
1
3
5
2
4
6
1
3
5
JP18
eDP Inverter Power Select (Optional)
2-3 On: +5V
1-2 On: +12V
(default)
3
1
2
3
1
2
JP18 is used to select the power level of the eDP Inverter power supply.