background image

 

 

 

INSTRUCTION MANUAL 

 

 

T

RUE

V

IEW

™ Model 1100 

Tension Indicator 

DOC 801-2573 

 

 

 

 

 

 

Summary of Contents for TrueView 1100

Page 1: ...INSTRUCTION MANUAL TRUEVIEW Model 1100 Tension Indicator DOC 801 2573...

Page 2: ...acing Orders Please e mail us at sales dfe com or call 603 332 6150 and ask for Sales Telephone 603 332 6150 Fax 603 332 3758 E mail info dfe com Internet www dfe com 2020 Dover Flexo Electronics Inc...

Page 3: ...or the information in this manual please contact us Email techsupport dfe com Telephone 603 332 6150 Observe all warning labels Never remove warning labels WARNING If this equipment is not connected o...

Page 4: ...2 3 STANDARD ELECTRICAL CONNECTIONS 3 1 Power Input 3 2 Tension Output Optional 3 3 Transducers Load Cells 3 3 OPERATION 4 3 1 MENU DISPLAY AND NAVIGATION 4 1 Operator Menu 4 2 Diagnostics 4 3 Calibr...

Page 5: ...internal fusing PTC resettable Tension Indicator Accuracy 1 2 drift at ambient maximum Calibration Range Up to 50 1 Processor 32 Bit ADC Resolution 16 777 216 24 Bit DAC Resolution 4 096 12 Bit Tensio...

Page 6: ...el over the unit from the back Insert into panel cut out from the front Attach panel mount brackets to the back of the indicator with the provided mounting screws and tighten the assembly against the...

Page 7: ...4 VDC 2 Tension Output Optional The tension output signal is provided in two options 0 10 VDC is available on Pins 9 Return and 11 0 10 VDC 4 20 mA is available on Pins 9 Return and 10 4 20 mA 3 Trans...

Page 8: ...information over time at the expense of rapid visual response to changes in tension Plot Update Time Choose 30 sec or 1 2 5 10 or 30 min and press SAVE to adjust time that tension displays before drop...

Page 9: ...u again to proceed Next tap Calibrate Select the units of measure for display Fig 5 The choices are lb oz g Kg or N After selection press OK You will now need to select a measurement range or scale Fi...

Page 10: ...thread it around the transducer roll and both adjacent idler rolls following the exact same path as the web which will be measured See the Right Way Wrong Way illustration Fig 11 for guidance Be sure...

Page 11: ...cessful Fig 14 Press BACK to return to the prior screen Re Calibrate if something occurred which made the calibration suspect or OK after which the indicator will very briefly flash a Calibration Succ...

Page 12: ...ING ERROR Will alert until the load cells are wired correctly Action Required Check wiring and retry Refer to page 3 to check for loose wires at the terminal blocks wiring shorts and ensure load cells...

Page 13: ...ard terms or the terms originally specified the Company may require full or partial payment in ad vance or upon delivery The Company reserves the right to make collection on any terms approved in writ...

Page 14: ...RIGHTS RESERVED PRINTED IN USA 307 PICKERING ROAD ROCHESTER NEW HAMPSHIRE 03867 4630 U S A TEL 603 332 6150 FAX 603 332 3758 E mail info dfe com Internet www dfe com CANADA EUROPE MEXICO UNITED KINGD...

Reviews: