Pic 8.27
NAME
DESCRIPTION
Ac�veP
Adjust the output ac�ve power in %
0-110%
OFF/Q(P)/PF(P)
/Q(U)/PF/Q(%)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
0-100%
0-1000s
Fun_ISO
Fun_RCD
Self-check
Island
Meter
Feed_IN %
Q-Mode
Vref
PF
Mul�ple reac�ve power control modes
Grid reference voltage for func�ons including
Q(U),PF(P),P(U)etc.
Power Fator
Insula�on resistance detec�on
Residual current detec�on
Inverter's self-check �me.The default value 60s
An�-islanding protec�on
If you want to use zero output mode,please set
Meter to ON and select OFF to view data only
It is used to deploy how much power can be
feed in to grid when the inverter works under
zero export mode.(For example,Feed_in=50% of
the 12KW modeland loadpower is 5KW. which
means Max 6KW power can befeed into grid
a�er inverter providing 5Kw to the load firstly.
RANGE
-1-0.8~+0.8-1
-100%-+100%
80-260V
ReactP
Adjust reac�ve power output in %
-
41
-