background image

Dewert User Manual 2000XL Series– Updated 05.2021/1 MDR                                                                Page 8 of 19 

the side guard to fold down through its own weight. Allow the side guard to fold all the way down until it 
engages automatically. 
Please note: Due to the two guides and guide pins, a small amount of force is only necessary when releasing 
the lock (= briefly removing the side guard guide pins). Do not pull or push when allowing the side guard to 
fold down (hardly any force is required). 
 
Folding up the side guard: Grasp the side guard with one hand in the middle of the guard frame at the end 
facing downwards (or with two hands on the left and right at the top). Push the side guard upwards and 
outwards slightly, thereby releasing the lock. Now hold the side guard loosely and fold it up until it engages. 

Please note:

 Do not use the side guard as a push handle.  

 

Laterally lowerable side guard (optional)

 

(Standard for models 2210XLE, 2210XL/H, 2215XL/H, 2250XL/H, 2255XL/H) 
Operating the side guard: 
Hold the centre of the rail of the side guard with one hand and release it by moving it 
minimally sideways (either towards the head or foot part). At the same time, use your other hand to pull out 
and turn the locking pin (red knob) located in the centre of the side guard underneath the upholstery frame. 
Press down or pull up the side guard using the rail until the locking pin engages audibly. After the locking pin 
has engaged, the side guard is secured in place. To check whether the 
side guard has engaged properly, move it sideways on the rail (either towards the head or foot part). Only 
limited movement should then be noticeable. 
 

Always operate the side guard with the necessary caution. Never operate the side guard if the hands, 
fingers, etc. of another person are located between the bars or on the mechanism of the side guard. 
Risk of being crushed/pinched!!! 
 

The laterally lowerable side guard is completely screwed in place. If the side guard becomes too loose or has 
excessive lateral play over time due to use, it can be readjusted by tightening the screws. The moving parts of 
the side guard should be re-lubricated slightly at regular intervals  
(spray oil, e.g. Ballistol). 

 

Side guard, lowerable, for side rail 

This side guard can be placed and fixed on any side rail using a clamp. By loosening the toggle screw of the 
clamp, the position and height of the inserted side guard can be shifted and adjusted respectively. Complete 
lowering below the upholstery level can only be achieved if the guide points  
in the direction of the upholstery when the side guard is inserted into the clamp.    

Please note:

 Never use the side guard as a push handle. It has not been designed for this purpose. 

 

 

2.7  Echocardiography tables  

The table for echocardiography treatment has a cut-out on the left-hand side in the upholstered surface. It can 
be closed with a cushion. The cushion can be pushed out from the bottom upwards (a slight amount of 
pressure is required). To close the cut-out, first place the cushion in the rear of the cut-out and then press it 
down into the upholstered surface (a slight amount of pressure is required). The lower side of the cut-out is 
not parallel to the upper side. There is a visible slant. The position of the cushion in the cut-out is thus clearly 
identifiable and there is no risk of it being accidentally pushed out. 

 

Caution: Do not reach under the cushion or into the open cut-out during height adjustment. Always 
remove instruments/equipment from the cut-out area before adjusting the height. 

   

Potential equalisation connector

 

A potential equalisation connector according to DIN 42801 is attached to the long side of the underframe on 
the left (side with the upholstery cut-out). This connection must be used if interference from electromagnetic 
radiation can be seen on the monitors during the examination, which could falsify the measured values. 
Despite compliance with the applicable EMC regulations, the use of highly sensitive examination equipment 
can cause this minimal radiation to become visible. Only use connectors that comply with DIN. Through 
additional wiring of the individual assemblies, there is conductive contact between them.  

The potential equalisation connector is marked with the symbol 

.    

 
 

Summary of Contents for 2000XL Series

Page 1: ...se 3 1 6 Commissioning 3 1 7 Safety notices 3 1 8 Model designation and type labelling 4 1 9 Meaning of the serial number 4 2 Operating manual 5 2 1 Table design 5 2 2 Height adjustment 5 2 3 Head par...

Page 2: ...st important safety information Correct operation of the device is essential for safe operation Therefore please familiarise yourself with the contents of these instructions for use before using the d...

Page 3: ...Hold and lift the table on the left and right hand side of the underframe The table must stand securely on its feet or castors on a level flat and solid surface Before use activate the brakes on the c...

Page 4: ...express permission of the manufacturer When transporting the table take hold of the underframe NOT the upper frame 1 8 Model designation and type labelling The exact model designation depends on the c...

Page 5: ...ke place beforehand see section 7 Alternatively the switch rails can also be led out to the short side of the table This facilitates height adjustment from the short sides of the table The lifting mot...

Page 6: ...end position head down feet up inclined position To lower press down the lying surface and operate the release lever at the same time Once the desired position has been reached let go of the release l...

Page 7: ...ose opening reach under the head part when the table is standing still and press the cushion out from the bottom upwards a slight amount of pressure is required To close it simply insert the cushion i...

Page 8: ...d by tightening the screws The moving parts of the side guard should be re lubricated slightly at regular intervals spray oil e g Ballistol Side guard lowerable for side rail This side guard can be pl...

Page 9: ...sm Comfort twin castors 100 or 125 mm individually lockable Paper roll holder for examination tables Paper roll holder for transport recovery tables Side rails Fastening clamp for side rail Infusion p...

Page 10: ...on equipment kg 75 80 75 80 75 80 75 80 Min max height mm 500 940 520 940 500 940 520 940 Adjustment time motor s 22 22 Head part adjustment range ratchets 0 30 0 30 Head part adjustment range gas sp...

Page 11: ...00 650 800 Head part length mm 750 750 570 750 Weight approx depending on equipment kg 105 105 125 135 125 135 Min max height mm 630 1050 630 1050 570 990 570 990 Head part adjustment range gas spring...

Page 12: ...35XLE 2035XL H Max length mm 1950 1950 Width mm 700 800 700 800 Head part length mm 750 750 Weight approx depending on equipment kg 75 80 75 80 Min max height mm 480 920 500 920 Adjustment time motor...

Page 13: ...es within the meaning of EN 50082 Part 1 and 2 Model 2052XLE 2053XLE is equipped with a second electric motor Both motors are connected to the mains by a power cable 4 3 Technical data for hydraulic s...

Page 14: ...manufactured in such a way that it will operate safely over a very long period of time if used as intended and in a correct manner Depending on the conditions of use place of use and care the expected...

Page 15: ...they cannot be triggered accidentally by patients users or third parties The actuator of this table is equipped with an integrated safety device to protect against unauthorised unintentional operation...

Page 16: ...Packaging Safety notice Pay attention to sharp edges and pointed objects during disposal The packaging materials produced are mainly o Cardboard Paper o Plastic o Wood when delivered on a pallet Pleas...

Page 17: ...th therapy Table operation and patient positioning on the table may only be performed by professionally trained persons who have been instructed in its use or who through experience with other similar...

Page 18: ...damaged All switches and supply lines undamaged Function check With electromotive adjustment Move all motors with the foot switch or the hand switch to both limit positions until automatic switch off...

Page 19: ...ssories Accessories such as belts belt pads belt guides paper roll holders armrests etc undamaged and is proper and secure fixing function possible All necessary toggle screws present Possible movabil...

Reviews: