1.  Safety information 

 
1.1  Applied symbols 

Safety instructions and key sections in these operating instructions are marked with the exclamation mark 
symbol on the left. Please pay particular attention to these instructions and sections.

 

 
Symbols used on the device, depending on the respective equipment: 

Observe instructions for use:                    

 

 

 

 

Risk of injury due to being pinched or crushed:                 

 

 

Caution, potential hazard:                                                    

 

            

Connection for potential equalisation according to DIN 42801:     

 

 
 

1.2  Applied standards  

This device has been designed and manufactured in accordance with national and international regulations. 
This ensures a very high level of equipment safety.  
The models described here comply with the following regulations and directives: 
 
 

Regulation (EU) 2017/745 

 

DIN EN IEC 60601-1 

 

DIN EN ISO 14971 

 

DIN EN 60601-2-52 partly based on 

 

DIN EN IEC 62353 

 

DIN EN ISO 10993-5/-10 

 

DGUV Regulation 3 

     
This device is a Class 1 medical device according to Regulation (EU) 2017/745 (MDR). 
 
 

1.3  Safety regulations 

This section contains a summary of the most important safety information: 
 
Correct operation of the device is essential for safe operation. Therefore, please familiarise yourself with the 
contents of these instructions for use before using the device. We recommend that you keep these 
instructions for use near the device for future reference.  
The device may only be used by authorised, instructed and competent persons who are sufficiently familiar 
with its adjustment mechanism or have read and understood the operating manual fully. The manufacturer 
cannot be held responsible for damage caused by or involving unauthorised persons. 

 

The user must ensure that the device is not accessible to unauthorised persons or cannot be operated by 
unauthorised persons even when left unattended. When leaving the device, it should be secured in such a 
way that unauthorised adjustment is impossible. 
 

Keep a sufficient safety distance to the device during all adjustment procedures. Special attention 
must be paid to the arms, hands, legs and feet of the user and the patient - 

RISK OF CRUSHING!

 

 

 

Make sure that there are no objects located directly around or underneath the device! 

 

 

 

 

 

1.4  Intended purpose 

The table is used for the ideal positioning of patients for the purpose of curative and disease treatment, 
examination, massage and health therapy. 

Summary of Contents for 2000XL Series

Page 1: ...se 3 1 6 Commissioning 3 1 7 Safety notices 3 1 8 Model designation and type labelling 4 1 9 Meaning of the serial number 4 2 Operating manual 5 2 1 Table design 5 2 2 Height adjustment 5 2 3 Head par...

Page 2: ...st important safety information Correct operation of the device is essential for safe operation Therefore please familiarise yourself with the contents of these instructions for use before using the d...

Page 3: ...Hold and lift the table on the left and right hand side of the underframe The table must stand securely on its feet or castors on a level flat and solid surface Before use activate the brakes on the c...

Page 4: ...express permission of the manufacturer When transporting the table take hold of the underframe NOT the upper frame 1 8 Model designation and type labelling The exact model designation depends on the c...

Page 5: ...ke place beforehand see section 7 Alternatively the switch rails can also be led out to the short side of the table This facilitates height adjustment from the short sides of the table The lifting mot...

Page 6: ...end position head down feet up inclined position To lower press down the lying surface and operate the release lever at the same time Once the desired position has been reached let go of the release l...

Page 7: ...ose opening reach under the head part when the table is standing still and press the cushion out from the bottom upwards a slight amount of pressure is required To close it simply insert the cushion i...

Page 8: ...d by tightening the screws The moving parts of the side guard should be re lubricated slightly at regular intervals spray oil e g Ballistol Side guard lowerable for side rail This side guard can be pl...

Page 9: ...sm Comfort twin castors 100 or 125 mm individually lockable Paper roll holder for examination tables Paper roll holder for transport recovery tables Side rails Fastening clamp for side rail Infusion p...

Page 10: ...on equipment kg 75 80 75 80 75 80 75 80 Min max height mm 500 940 520 940 500 940 520 940 Adjustment time motor s 22 22 Head part adjustment range ratchets 0 30 0 30 Head part adjustment range gas sp...

Page 11: ...00 650 800 Head part length mm 750 750 570 750 Weight approx depending on equipment kg 105 105 125 135 125 135 Min max height mm 630 1050 630 1050 570 990 570 990 Head part adjustment range gas spring...

Page 12: ...35XLE 2035XL H Max length mm 1950 1950 Width mm 700 800 700 800 Head part length mm 750 750 Weight approx depending on equipment kg 75 80 75 80 Min max height mm 480 920 500 920 Adjustment time motor...

Page 13: ...es within the meaning of EN 50082 Part 1 and 2 Model 2052XLE 2053XLE is equipped with a second electric motor Both motors are connected to the mains by a power cable 4 3 Technical data for hydraulic s...

Page 14: ...manufactured in such a way that it will operate safely over a very long period of time if used as intended and in a correct manner Depending on the conditions of use place of use and care the expected...

Page 15: ...they cannot be triggered accidentally by patients users or third parties The actuator of this table is equipped with an integrated safety device to protect against unauthorised unintentional operation...

Page 16: ...Packaging Safety notice Pay attention to sharp edges and pointed objects during disposal The packaging materials produced are mainly o Cardboard Paper o Plastic o Wood when delivered on a pallet Pleas...

Page 17: ...th therapy Table operation and patient positioning on the table may only be performed by professionally trained persons who have been instructed in its use or who through experience with other similar...

Page 18: ...damaged All switches and supply lines undamaged Function check With electromotive adjustment Move all motors with the foot switch or the hand switch to both limit positions until automatic switch off...

Page 19: ...ssories Accessories such as belts belt pads belt guides paper roll holders armrests etc undamaged and is proper and secure fixing function possible All necessary toggle screws present Possible movabil...

Reviews: