Description (fig. A)
Your D
E
WALT DW86 Circular Saw is a versatile
Power Tool that has been designed for professional
sawing applications.
1 ON/OFF-switch
1a Lock-off button
2 Front handle
3 Bevel adjustment and locking system
4 Lower blade guard and lever
5 Saw shoe
6 Dust extraction outlet
7 Saw blade locking bolt
8 Spindle lock
9 Depth of cut adjustment
10 Depth of cut scale
11 Riving knife
12 Parallel fence
13 Mark for straight cut
14 Mark for bevel cut
15 Locking screw for parallel fence
16 Parallel fence cut-off indicator
17 Saw blade wrench
18 Depth of cut indicator
Electrical safety
The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
E
WALT tool is double insulated in
accordance with EN 50144; therefore no
earth wire is required.
Mains plug replacement (U.K. & Ireland
only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
E
WALT repair agent or a qualified electrician.
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
.
For 115 V tools, use plugs to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
triple-core extension cable suitable for the power
input of this tool (see technical data). The minimum
conductor size is 1.5 mm
2
.
When using a cable reel, always unwind the cable
completely. Also refer to the table below.
Conductor size (mm
2
)
Cable rating (Amperes)
0.75
6
1.00
10
1.50
15
2.50
20
4.00
25
Cable length (m)
7.5
15
25
30
45
60
Voltage
Amperes
Cable rating (Amperes)
115
0 - 2.0
6
6
6
6
6
10
2.1 - 3.4
6
6
6
6
15
15
3.5 - 5.0
6
6
10
15
20
20
5.1 - 7.0
10
10
15
20
20
25
7.1 - 12.0
15
15
20
25
25
-
12.1 - 20.0
20
20
25
-
-
-
220/240
0 - 2.0
6
6
6
6
6
6
2.1 - 3.4
6
6
6
6
6
6
3.5 - 5.0
6
6
6
6
10
15
5.1 - 7.0
10
10
10
10
15
15
7.1 - 12.0
15
15
15
15
20
20
12.1 - 20.0
20
20
20
20
25
-
Summary of Contents for DW86
Page 1: ...78 DW86 ...
Page 3: ...80 ...
Page 4: ...81 A 3 5 14 13 15 17 1a 1 2 7 11 4 12 16 6 19 15 8 10 20 30 40 50 10 18 9 ...
Page 5: ...82 B C D 13 10 20 30 40 50 1a 1 10 20 30 40 50 10 9 2 8 ...
Page 6: ...83 G F E 12 16 15 13 14 3 5 7 4 17 6 11 max 5 mm 5 mm 8 ...
Page 81: ...75 ...
Page 82: ...76 ...
Page 84: ...84 ...
Page 85: ...85 ...