background image

SB-4-391-W  (12/2017)

1 / 6

www.carlisleft.com

Repair Kit KK-5007

Figure 1  

TLC-555 & TGC-545 

DRIP FREE SUCTION CUPS

DESCRIPTION

Models:  

■ 

TLC-555  – One quart capacity, 

 

 

  Non-stick coating lined cup

 

TGC-545 – One quart capacity

These drip free suction cups have a unique, two position valve which 

permits selection of either a drip free spraying mode or a conventional 

open vent mode.

In the drip free position, air is directed through the vent in the lid to a 

channel beneath the lid gasket before entering the cup at the valve.  This 

allows the cup to be tilted when full without dripping paint through the 

vent.  The cup can also be inverted while spraying without leaking.

The open position isolates the channel and opens a direct vent into the cup.

The position of the valve is indicated by alignment of the hole in the valve 

slot with the marks cast on the lid. These positions are identified as "O" 

for vent open and

 "D/F" 

for Drip Free.

Note

Non-stick Coating Lined  Cup  - Only use a wooden or plastic paddle 

or mixer for mixing material in the cup (7).  A metal paddle or mixer 

can scratch the non-stick coating.

Note

For Non-stick Coating Lined Paint Cups, variation in the color of 

the non-stick coating is normal.  This variation is the result of the 

normal production process used with this type of coating.  We have 

selected this particular grade of non-stick coating because it provides 

the best

 overall performance and

 maximum durability

 possible.

OPERATION

Open Vent Mode

 "O"- To operate in the open vent mode, rotate the 

valve with a screwdriver or coin so that the hole in the valve slot is aligned 

with the "O" on the lid.  See Figure 2.

If the valve slot hole should plug while operating in the "O" vent mode, 

use a pointed tool such as a nail or drill bit to probe through the valve 

slot hole to clear away the obstruction.

Figure 2 –  Open Vent Mode

Drip Free Mode 

"D/F" – To operate in the drip free mode, rotate the 

valve with a screwdriver or coin so that the hole in the valve slot is aligned 

with the "D/F" on the lid.  See Fig. 3

Do not probe through the channel vent hole at any time. Do 

not probe through the valve slot hole while the valve is in the 

"D/F" position.  These holes are sealed by a gasket and 

gasket damage could result.  See Figs. 2 & 3.

Valve in 

Open

 Position

Channel
Vent Hole
(Do Not Probe)

Valve slot
hole can be
probed to clean.

Gasket

Channel

Channel
Vent Hole

Gasket shown 
partially removed

Lid Top

Lid Underside

D/FO

  Government NSN # 4940-01-208-8876  = TLC-555

Important: Before using this equipment, read all safety 

precautions and instructions. Keep for future use.

EN

SERVICE MANUAL

IMPORTANT! DO NOT DESTROY

It is the Customer's responsibility to have all operators and service personnel read and understand this manual.

Contact your local DeVilbiss representative for additional copies of this manual. 

READ ALL INSTRUCTIONS BEFORE OPERATING THIS DEVILBISS PRODUCT.

Summary of Contents for TGC-545

Page 1: ...culargradeofnon stickcoatingbecauseitprovides the best overall performance and maximum durability possible OPERATION Open Vent Mode O To operate in the open vent mode rotate the valve with a screwdriver or coin so that the hole in the valve slot is aligned with the O on the lid See Figure 2 If the valve slot hole should plug while operating in the O vent mode use a pointed tool such as a nail or d...

Page 2: ...ntact your material supplier Inhaling Toxic Substances Certain materials may be harmful if inhaled or if there is contact with the skin Follow the requirements of the Safety Data Sheet sup plied by your coating material manufacturer Adequate exhaust must be provided to keep the air free of accumulations of toxic materials Use a mask or respirator whenever there is a chance of inhaling sprayed mate...

Page 3: ...rly Do not lubricate the cam General For routine cleaning it is not necessary to remove the lid gasket It is not necessary or desirable to remove the valve for any cleaning procedure The valve can be depressed from the outside to assist in removal of the gasket for gasket replacement or when cleaning dried paint from the channel The valve should not be forced past the shoulder which retains it in ...

Page 4: ...ket Kit of 3 1 5 TGC 9 K5 Tri Seal Lid Gasket Kit of 5 1 6 TGC 404 Lid Assembly Quart 1 7 KR 428 2 Suction Cup Assy Quart 1 TLC 401 Suction Cup Assy Non stick Quart KK 5007 Repair Kit includes Ref Nos 1 5 Repair kit contains enough parts to repair one complete assembly Suffix K3 designates a kit of multiple parts Example TGC 407 1 K3 is a kit of 3 drip free valves Registered Trademark of Tri Seal ...

Page 5: ...SB 4 391 W 12 2017 5 6 EN www carlisleft com NOTES ...

Page 6: ...as carlisleft com mx Tel 52 55 5321 2300 Fax 52 55 5310 4790 Japan overseas sales carlisleft co jp Tel 81 45 785 6421 Fax 81 45 785 6517 Germany info carlisleft eu Tel 49 0 6074 403 1 Fax 49 0 6074 403 281 Australia sales carlisleft com au Tel 61 0 2 8525 7555 Fax 61 0 2 8525 7575 Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice DeVilbiss Ransb...

Reviews: