10. Service Mode
Field Service Ver. 1.0 Apr. 2005
90
ineo 161
ineo 210
Adjustment / Setting
10.3.2
ADJUST
A. PRN MAIN REGIST
Function
Test Copy
Adjust
Purpose/Use
To adjust by varying the starting position of image writing in the main scanning direc-
tion.
✽
When the image on the copy deviates in the CD direction
✽
When the PH Unit has been replaced
Setting/
Procedure
Press the Start key to start a test copy
cycle.
Setting range: 60 to 140 (1 step: 0.1 mm)
Adjustment
Procedure
Adjust so that width A on the test pattern pro-
duced falls within the specified range.
Specifications
20 ± 2.0 mm
1. Load the Paper Feed Tray/1 with A4 crosswise paper.
2. Enter Function of the Service mode.
3. Select “Print Test Pattern” and then “Test Pattern1.” Then, press the Start key.
✽
This will produce a test pattern.
4. Check to see if width A on the test pattern falls within the specified range.
If width A falls outside the specified range, perform the following steps to make an
adjustment.
5. Select “Adjust” of “PRN Main Regist.”
6. Using [
▲
/
▼
] key, select the appropriate setting value.
7. Press the [Yes] key to validate the setting value selected in step 6.
Adjustment Instructions
If width A on the test pattern is longer than the specifications, decrease the setting
value.
If width A on the test pattern is shorter than the specifications, increase the setting
value.
If a single adjustment procedure does not successfully bring width A into the speci-
fied range, repeat steps 5 through 7.
4035D519AA
A