FrameMaker Ver5.5E(PC) Di152/Di183 MECHANICAL/ELECTRICAL
01.09.05
M-24
12-5.
Toner Replenishing Mechanism
• Toner is supplied from the Toner Bottle to the Developer Mixing Chamber.
1. The coupling is turned by the motor, which turns the Toner Bottle.
2. To regulate the amount of toner supplied from the Toner Bottle, there is a Metering
Chamber provided in the outer race of the coupling.
3. When the Toner Bottle turns, toner in the Metering Chamber drops.
4. Toner from the metering chamber is conveyed by the Toner Conveying Screw into the
Developer Mixing Chamber.
5. The Toner Conveying Screw is turned by the motor.
Elevtrical Component
Control Signal
ON
OFF
Wiring Diagram
M6
PWB-A PJ19A-6
L
H
4-B
4021M020AB
4021M021AB
4021M022AA
4021M023AA
Toner Bottle
coupling
Developer Mixing Chamber
Toner Conveying Screw
Metering
Chamber