FrameMaker Ver.5.5E(PC) Di152/Di183 TROUBLESHOOTING
01.09.04
T-24
(2)
C0045: Fusing Cooling Fan Motor malfunction
Relevant Electrical Parts
Fusing Cooling Fan Motor (M3)
Master Board (copier: PWB-A)
Step
Check
Result
Action
1
Fusing Cooling Fan Motor (M3) turns
when the Power Switch is turned ON.
NO
• Check for overload.
2
The following voltage is supplied to
the Fusing Cooling Fan Motor (M3).
<Check Procedure>
Check voltage across a Master Board
(copier: PWB-A) pin and GND when
the Power Switch is turned ON.
• Voltage across PJ10A-4 and GND
DC8 V during rotation at deceler-
ated speed
DC24 V during rotation at full
speed
YES
• Change Fusing Cooling Fan Motor
(M3).
3
The following voltage is supplied to
the Fusing Cooling Fan Motor (M3).
<Check Procedure>
Check voltage across a Master Board
(copier: PWB-A) pin and GND when
the Power Switch is turned ON.
• Voltage across PJ10A-6 and GND
DC0 V when energized
NO
• Change Fusing Cooling Fan Motor
(M3).
YES
• Change Master Board (copier:
PWB-A).
PWB-A
Master Board
FUSING SECTION
Fusing Cooling
Fan Motor
4022T526AA
Summary of Contents for D1531iD
Page 2: ...FrameMaker Ver5 5E PC Di152 Di183 GENERAL 01 08 27 GENERAL 14413 ...
Page 3: ......
Page 5: ......
Page 15: ......
Page 16: ...FrameMaker Ver5 5E PC Di152 Di183 MECHANICAL ELECTRICAL 01 09 05 MECHANICAL ELECTRICAL 14413 ...
Page 17: ......
Page 73: ......
Page 85: ......
Page 89: ......
Page 161: ......
Page 163: ......
Page 193: ......
Page 194: ...FrameMaker Ver 5 5E PC Di152 Di183 TROUBLESHOOTING 01 09 04 TROUBLESHOOTING 14390 ...
Page 195: ......
Page 259: ......