FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
D-66
(3)
Adjustment of the Gap between the Doctor Blade and Sleeve Roller (Db Adjust-
ment)
Requirement
• The gap between the Doctor Blade and the Sleeve Roller should be 0.39 ± 0.04 mm (as
set using the jigs).
<Adjustment Procedure>
1. Remove the IU.
2. Separate the Cleaning Assy from the Developing Assy.
3. Remove the PC Drum, Main Erase, PC Drum Charge Corona Assy, and Ozone Filter.
5. Remove three screws and the Developer Scattering Prevention Plate.
4. Install the Ds Collar Positioning Jigs.
NOTE
• Ready a PC Positioning Jig (Pivot Shaft) sepa-
rately. (It can be ordered. For details, see the
Parts Manual.)
4022D018AC
Ds Collar Positioning Jigs
PC Positioning Jig
6. Remove three screws and the Doctor Blade.
4022D019AA
7. Using a small piece of paper, remove developer
from the shaded area on the surface of the
Sleeve Roller and put it in the Developer Mixing
Chamber.
8. Vacuum the developer left on the Sleeve Roller.
4022D036AA
Piece of paper
9. Temporarily secure the Doctor Blade using three
new screws.
NOTE
• Whenever a Db adjustment is made, use new
screws (to which lock paint has been applied).
4022D020AA
Summary of Contents for D1531iD
Page 2: ...FrameMaker Ver5 5E PC Di152 Di183 GENERAL 01 08 27 GENERAL 14413 ...
Page 3: ......
Page 5: ......
Page 15: ......
Page 16: ...FrameMaker Ver5 5E PC Di152 Di183 MECHANICAL ELECTRICAL 01 09 05 MECHANICAL ELECTRICAL 14413 ...
Page 17: ......
Page 73: ......
Page 85: ......
Page 89: ......
Page 161: ......
Page 163: ......
Page 193: ......
Page 194: ...FrameMaker Ver 5 5E PC Di152 Di183 TROUBLESHOOTING 01 09 04 TROUBLESHOOTING 14390 ...
Page 195: ......
Page 259: ......