7
4
Supported Clusters
4.1
Common clusters for each end point
The ZCL “General Function Domain” clusters in this section are implemented as server clusters. Refer
to ZigBee Cluster Library Specification.
http://www.zigbee.org/Specifications.aspx
4.1.1
Basic – Cluster id 0x0000
Only the first set has mandatory attributes, also the optional attributes that can be relevant to a
Develco device are all in set 0x000
4.1.1.1
Attribute
Id#
Name
type
range
Man
/Opt
Relevance and ref.
0x0
ZCLVersion
Uint8
Type range
M
0x4
ManufacturerName
String
0-32 byte
O
4.1.1.1.1
0x5
ModelIdentifier
String
0-32 byte
O
4.1.1.1.2
0x7
PowerSource
8 bit
enum
Type range
M
4.1.1.1.1
ManufacturerName
“Develco Products A/S”
4.1.1.1.2
ModelIdentifier
“ZHOT101 - ZigBee Occupancy, Temperature & Light Sensor”
4.1.2
Identify – Cluster id 0x0003
4.1.2.1
Attribute
Id#
Name
type
range
Man
/Opt
Relevance and ref.
0x0000
IdentifyTime
Uint16
Type range
M
4.1.2.2
Commands
The identify cluster has 2 commands as server.
Id#
Name
Payload
Man
/Opt
Relevance and ref.
0x00
Identify
Uint16 - Identify Time (seconds)
M
0x01
Identify Query
none
M
The identify cluster has 1 command as client.
Id#
Name
Payload
Man
/Opt
Relevance and ref.
0x00
Identify Query
Response
Uint16 - Identify Time (seconds)
M
4.1.3
Power Configuration - Cluster id 0x0001
The power configuration cluster is described in ZigBee Cluster Library Specification section 4.8
4.1.3.1
Attribute
Id#
Name
type
range
Man
/Opt
Relevance and ref.
0x0020
BatteryVoltage
Uint8
0x00 - 0xFF
O