Parameter Name
Type
Range
Default value [, Unit] Description
Device
Device related submenu
Alias
STR
DB4005
Alias name for device
Date / Time
Date / Time settings
Date
DATE
01-Jan-2012 … 31-Dec-2100
dd-mm-yyyy
Manual set Date
Time
TIME
0:0:0 … 23:59:59, step 1
hh:mm:ss
Manual set Time
Timezone
TZONE
-12:00 … 14:00, step 30 min
hh:mm
Timezone
Front Panel
Front panel settings
Display Brightness
INT
0 … 100, step 10
50, %
Display brightness
Display Contrast
INT
0 … 100, step 10
100, %
Display contrast
LED Brightness
INT
0 … 100, step 10
60, %
LED bars brightness
Screen Saver
ENUM
Disable, 1, 2, 5, 10
2, min
Screen saver control
Panel Timeout
TIMER
10 … 600, step 10
10, sec
Panel inactivity timeout
Loss
Audio loss LED settings
Threshold
INT
-100 … 0, step 1
-50, dB
Active threshold level
Timeout
TIMER
1 … 60, step 1
1, sec
LED activation delay
Home Screen
INT
0 … 3, step 1
1
Select Device’s home screen
Fan Control
ENUM
Auto, 25, 50, 75, 100
Auto, %
Fan speed control
Factory Defaults
Factory defaults settings
Apply to
ENUM
None, Channels, Retain Comm, All
None
Selects parameter group to apply defaults
Execute
ENUM
Done, Proceed
Done
Revert defaults to selected parameter group
NOTE 1: