![DEVA Broadcast DB3011 Maintenance And Operation Instruction Manual Download Page 52](http://html.mh-extra.com/html/deva-broadcast/db3011/db3011_maintenance-and-operation-instruction-manual_2488554052.webp)
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 52 -
Alarm notifications
[E-mail] – global enable/disable E-mail notification;
[SNMP] – global enable/disable SNMP notification;
[GPO] – global enable/disable GPO actions.
NOTE:
If the monitoring option is disabled, notifications will not be sent, nevertheless whether
they are enabled or disabled.
RF, HD DAAI, HD CDNR, FM/IP Left Audio, FM/IP Right Audio Alarms
The settings applied to these alarms - are identical and are explained in details below.
Range
– interactive slider used to adjust the
Low&High thresholds
at which an alarm will be
generated;
Thresholds
– sets the desired
Low&High thresholds
(as explained above) but in figures.
Trigger Time
– waiting time before active alarm is generated;
Release Time
– waiting time before idle alarm is generated;
Once the
Range
,
Thresholds
,
Trigger
and
Release times
are set, the preferred alarm type should
be selected.
PLEASE HAVE IN MIND
that if the alarm notification is globally disabled, notification will
not be sent, and the event will only be registered in the Log.
HD Radio Loss, Stereo Loss, IP Link, Internet Stream Alarms
The settings applied to these alarms are identical and are explained in details below.
Enable
– In order for the alarm to be generated, the function should be enabled;
Trigger Time
– waiting time before active alarm is generated;
Release Time
– waiting time before idle alarm is generated.
HD Radio Loss Alarm
,
Stereo Loss Alarm
,
IP Link Alarm
and
Internet Stream Alarm
are
flags related alarms, meaning that:
-
HD Radio Loss
– when the indicator points at
OK
on the interactive slider, the device is
working properly. If the indicator is under
No signal
, an alarm will be generated because of HD
Radio Loss.
-
Stereo Loss
– when the indicator points at
Stereo
on the interactive slider, the device is
working properly. If the indicator is under
Mono
, an alarm will be generated because of Stereo
loss.
-
IP Link
– when the indicator points at
UP
on the interactive slider, the device is working
properly.If the indicator is under
Down
, an alarm will be generated because the IP link is lost.
-
Internet Stream
– when the indicator points at
Connected
on the interactive slider, the device
is working properly. If the indicator is under
Idle
, an alarm will be generated because the device
will not be able to obtain stream.
We recommend, as a preferred notification method in case
IP Link alarm
is generated,
GPO
to be set as when IP link is missing
and
SNMP
could not be sent, and he event will only be
registered in the
Log
. You will be notified of the event upon the IP link is restored.
NOTE: