![DEV 5071 Documentation Download Page 36](http://html.mh-extra.com/html/dev/5071/5071_documentation_2488487036.webp)
Customer Documentation DEV 5071
36
Copyright DEV Systemtechnik GmbH 2007-2017
5.4.5.4 SNMP Configuration
The currently logged in user has to have "admin" permission to access the
SNMP Configuration functionality, where the SNMP setup of the device can
be modified.
Within the SNMP setup, the settings for the "System Name" and the "System
Location" can be modified. An "Administrator" can be defined and the
passwords for the "Read Community" and for the "Write Community" can be
set.
The check box below these entries is used to enable the switching between
Local Mode and Remote Mode via SNMP, please refer to chapter 5.5.4.2.1.
Additionally, up to four Trap Receiver IP Addresses can be defined via the
IP address and the port in the format <ip-address>{:<port>}, e.g.
192.168.0.29:121. If <port> is not specified, the standard SNMP trap port
162 is assumed.
Finally, a click on the download icon initiates the download of the MIB of the
device.
The three buttons at the bottom of the window are used for the handling of
the data entered above. The Cancel button is used for discarding changes
possibly applied. Save (in Local Mode, only!) downloads the data to the
CPU module to be stored there permanently and reboots the device. A click
on the button Exit closes the functionality and initiates the return to the
Setup Tab.