21.4.15
Instruction manual UNIGATE
®
IC - Powerlink V. 2.3
13
Deutschmann Automation GmbH & Co. KG
Hardware design
* The supply voltage is 3.3V +/- 5 %, max. 500 mA DC.
The Ethernet signals are galvanically isolated. The insulation voltage is 1000 Vrms.
*) Anode of the green LED
3.3V ± 5%, < 500mA
V
IL
V
IH
IN
Reset
< 0.25V / 1mA
>1.5V / 10µA
IN
Logic
< 0.5V / 0.4mA
>1.5V / 10µA
V
OL
V
OH
OUT
Logic
< 0.6V / 1mA
>2.3V / 0,1mA
OUT
Driver
< 0.5V / 4mA
>2.5V / 4mA
3.2.1
-Boot enable
The IC is started in the firmware update mode with the level GND during the power up process.
See also chapter 13 on page 36.
3.2.2
Load out (SPI-Master: SS0-)
Strobe signal for the synchronous serial interface. With the positive edge at this output data is
taken from the connected shift registers to the physical outputs.
In SPI mode this Pin serves as a low-active Slave-Select-Signal.
3.2.3
Data out (SPI-Master: SS1-)
On this line data is output on the synchronous serial interface. The most significant bit of the data
is output first.
In SPI mode this Pin serves as a low-active Slave-Select-Signal.
3.2.4
Data In (SPI: MISO)
Data is read in on the synchronous serial interface via this signal. The most significant bit of the
data is expected first.
In SPI mode this Pin serves as data transfer from Slave to Master.
3.2.5
Load In (SPI: MOSI)
This pin is the strobe signal for the input data of the synchronous serial interface.
In SPI mode this Pin serves as data transfer Master to Slave.
3.2.6
Clock
This signal is the clock line for the synchronous serial interface. That signal is equally valid for
data input and data output.
26
IN
Logic
-Config Mode
signal to start the configuration mode
internally pulled up with
10 k
27
OUT
Logic
DbgTX
serial Debug TX
28
IN
Logic
DbgRX
serial Debug RX
internally pulled up with
10 k
29
IN
Logic
RX
serial data RX
internally pulled up with
10 k
30
OUT
Logic
TX
serial data TX
31
OUT
Logic
TE
transmit enable
32*
GND
GND
ground supply voltage of the IC