24.7.12
Instruction manual LOCON 24, 48, 64, LTC, TERM 24 and TERM 6 V. 8.8
31
Deutschmann Automation GmbH & Co. KG
LOCON 24, 48 and 64 options
The value „EncoderErrorStep“ by which the error counter is counted up is set by the encoder
type; that means a value between 100 and 199 is set as encoder type at a device with activated
encoder test (only possible for absolute shaft encoders) Then the value „EncoderErrorStep“
results as (encoder type - 100). If, for instance, 123 is entered as encoder type, the encoder
counter is counted up by 23 at each incorrect encoder value.
Error 100 is not suppressed if the encoder is not connected on units for absolute shaft encoders
with a resolution of 360 or 1,000 increments featuring this option.
7.6
Speed display
Optionally, a 'hardware' speed display at the upper 8 outputs of the cam control as a binary value
is available. In this case, the last output corresponds to the most significant bit of the speed, e.g.:
33 rpm = 21 (hex) = 00100001 (binary). If the displayable range of 255 is exceeded, the value at
the input is frozen at 255.
LOCON 24
LOCON 24A
LOCON 48
LOCON 64
7.7
Direction-cams
This option allows you to define, for each output, with what direction of rotation the outputs are to
be switched. Three options (per output) can be used:
•
Switching in both directions
•
Switching in positive direction only
•
Switching in negative direction only
The evaluation only takes place at the cam’s edge, that means, in case the control detects an
edge (switch on- or switch off edge) the output is always updated whenever the direction of rota-
tion corresponds to the programmed direction.