![DEUTSCHMANN AUTOMATION SPEEDY Series Instruction Manual Download Page 14](http://html1.mh-extra.com/html/deutschmann-automation/speedy-series/speedy-series_instruction-manual_2488412014.webp)
SPEEDY switching modes
Deutschmann Automation GmbH & Co. KG
14
Instruction manual dynamic switching accelerator SPEEDY V. 3.1
30.1.20
5.3
Switching mode 2
In switching mode 2, input 1 is switched to output 1 and input 2 is switched to output 2. Input 3 is
an Enable input. If there is no signal at input 3, input 1 and input 2 are inoperable. The duration of
the overexcitation pulses is set at input 4.
Picture 3:
Switching mode 2
Input 1
Input 2
Input 3
Output 1
Output 2
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
+24 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
+24 VDC
0 VDC
0 VDC
0 VDC
+24 VDC
+24 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
+24 VDC
0 VDC
0 VDC
+24 VDC
0 VDC
+24 VDC
+UB
0 VDC
0 VDC
+24 VDC
+24 VDC
0V
+UB
+24 VDC
+24 VDC
+24 VDC
+UB
+UB
Input 4
Pulse
0 VDC
2 ms
+24 VDC
5 ms