5.4
Pin assignment TERM 5/6
The external control unit is suitable for connection through a 5-pin-screw-plug-connection with
the following assignment:
Picture 9: Pin assignment TERM 5 / TERM 6
5.5
Display element TERM 5
LED Prg.Mode Flashes during programming mode.
LED On
Shines when displaying and flashes when programming a cam-turn-on instant.
Shines together with the Off-LED, in case on the program- or output-display (Pxx
or Axx on the display) cams exist in this program and output.
LED Off
Shines when displaying and flashes when programming a cam-turn-off instant.
(see also LED On)
LED Zero
Shines when displaying and flashes together with the LED Prg.Mode when pro-
gramming the zero offset.
Flashes (without LED Prg.Mode) when shifting a complete cam track.
Flashes together with the LED Function when programming the inversion of the
rotational direction.
LED Function
At LOCON 7 without function, at LOCON 9 idle time indication.
LED Error
Flashes in case an error condition appeared. At the same time the correspond-
ing error number is presented on the display, that is described more detailed in
the appendix.
LEDs 1-16
Flash in case the corresponding output (1 - 16) is active (24 V applied at the out-
put).
Pin No.
Significance
1
24 Volt DC
2
GND
3
Rx-TERM (DICNET-)
4
Tx-TERM ()
5
GND