Owner’s Manual
DUCTLESS SINGLE ZONE HEAT PUMP
18 SEER INVERTER
9 000 to 24 000 BTU/hr
Models:
LPD09KCH18SLPD12KCH18SLPD18KCH18SLPD24KCH18S
Please read this owner’s manual carefully
before operating the unit and keep it for future reference.
Page 1: ...SS SINGLE ZONE HEAT PUMP 18 SEER INVERTER 9 000 to 24 000 BTU hr Models LPD09KCH18S LPD12KCH18S LPD18KCH18S LPD24KCH18S Please read this owner s manual carefully before operating the unit and keep it...
Page 2: ...ter installation 41 Test and operation Test operation 41 Attachment 42 44 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or l...
Page 3: ...components that produced by other manufacturers 6 After verification the problem or dispute is caused by the quality specification or majeure 7 The damage is caused by natural calamities bad using en...
Page 4: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...
Page 5: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...
Page 6: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...
Page 7: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...
Page 8: ...her must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be 5...
Page 9: ...ns FCC STATEMENT accordance with the instructions may cause harmful harmful interference in a residential installation This undesired operation frequency energy and if not installed and used in Howeve...
Page 10: ...tion of the device This equipment complies with FCC s and IC s RF radiation exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must be installed and oper...
Page 11: ...mperature range Indoor side DB WB C F Outdoor side DB WB C F Maximum cooling 26 7 19 4 80 66 9 46 1 23 9 115 75 Maximum heating 26 7 80 23 9 18 3 75 64 9 The operating temperature range outdoor temper...
Page 12: ...please refer to actual products Parts Name air inlet panel aux button horizontal louver air outlet Actual product may be different from above graphics please refer to actual products NOTICE remote con...
Page 13: ...l For some model For some model For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display For some model heating indicator temp indicat...
Page 14: ...TIMER OFF button SLEEP button button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light Temp display type Set temp Outdo...
Page 15: ...some models Introduction for buttons on remote controller Note After putting through the power the air conditioner will give out a sound Operation indicator is ON red indicator the colour is differen...
Page 16: ...blowed after the unit is stopped to avoid mould Having set X FAN function on After turning off the unit by pressing ON OFF button indoor fan will continue running for a few minutes at low speed In th...
Page 17: ...r button once increase or decrease set temperature 1 1 F Holding or button 2s later set temperature on remote controller will change quickly On releasing button after setting is nished temperature ind...
Page 18: ...Fi button 9 LIGHT button 10 Press this button to turn off display light on indoor unit icon on remote controller disappears Press this button again to turn on display light icon is displayed TIMER ON...
Page 19: ...ton can set the time for timer off After pressing this button icon disappears and the word OFF on remote controller blinks Press or button to adjust TIMER OFF setting After each pressing or button TIM...
Page 20: ...emote controller will display 46 heating Function introduction for combination buttons Temperature display switchover function Under OFF status press and MODE buttons simultaneously to switch temp era...
Page 21: ...two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall NOTICE During o...
Page 22: ...enance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use v...
Page 23: ...and then put it in a shady and cool place to dry panel cover tightly The lter should be cleaned every three months If there is much dust in the operation environment clean frequency can be increased...
Page 24: ...nage pipe is damaged 1 Disconnect power supply Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air...
Page 25: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...
Page 26: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...
Page 27: ...ess devices etc Disconnect power put back power and then turn on the unit again Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing in...
Page 28: ...an be eliminated after restarting the unit If not please It can be eliminated after restarting the unit If not please F0 Note service Malfunction analysis When below phenomenon occurs please turn off...
Page 29: ...east 15 cm At least 15 cm At least 183 cm Space to the floor At least 300 cm he obs Space to t truction Space to the obstruction Space to the obstruction Space to the obstruction Drainage pipe Space t...
Page 30: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...
Page 31: ...end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note Please contact the local agent for installation Don t us...
Page 32: ...ly to sunlight or strong wind 3 The location should be able to withstand the weight of outdoor unit 4 Make sure that the installation follows the requirement of installation dimension diagram 5 Select...
Page 33: ...er to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with nation...
Page 34: ...ove 150mm Space to the wall above 150mm 55mm Rear piping hole LPD09KCH18S 31 Installation of indoor unit Step one choosing installation location Step two install wall mounting frame rm it with the cli...
Page 35: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...
Page 36: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...
Page 37: ...reak must be installed in the line The circuit break should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the...
Page 38: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...
Page 39: ...st joint For the unit with cooling capacity of 2300 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capaci...
Page 40: ...09 12K 1 Remove the screw cap of valve a aim the pipe joint at the bellmouth of pipe 2 Pretightening the union nut wi hand 3 Tighten the union nut with torque wrench by referring to the sheet below g...
Page 41: ...d heating unit Note Never cut the power connection wire to prolong or shorten the distance During heating operation the condensate and defrosting water should be drained out reliably through the drain...
Page 42: ...consists of one 25 and two kidney plugs The figures in this manual may be different with the material objects please refer to the material objects for reference drain holes drain holes drain holes Dr...
Page 43: ...ecreases there may be leakage 5 Remove the piezome r open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging...
Page 44: ...amaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are removed...
Page 45: ...requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amo...
Page 46: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...
Page 47: ...ng pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander No...
Page 48: ...66129929527...