![Detroit Diesel DDEC VI Application And Installation Download Page 370](http://html.mh-extra.com/html/detroit-diesel/ddec-vi/ddec-vi_application-and-installation_2488033370.webp)
FEATURES
5.26.7
ZF ASTRONIC TRANSMISSION
Programming Requirements and Flexibility
The parameters listed in Table 5-87 must be set for the ZF Astronic transmission.
Parameter
Group
Parameter
Setting
2
Transmission Type
DIRECT ENGINE START
2 – ZF Astronic Direct Start
MCM ENGINE START
5 – ZF Astronic MCM Start
13
Clutch Switch Con
fi
g
0 – Disabled
13
4 08 DI Selection
0 – Disabled
13
Trans Neutral Input Con
fi
g
1 – Info from J1939
8
Vehicle Speed Sensor
3 – J1939 (ETC1)
3
Adjusted Idle Con
fi
guration
3 – Enabled if Neutral and Park Brake
3
Max Adjusted Idle
<700 rpm
22
0 Speed Governor TSC1 Condition
0 – Series 60
16 – MBE900/4000
22
1 Speed Governor TSC1 Condition
0 – Series 60
16 – MBE900/4000
22
2 Speed Governor TSC1 Condition
0 – Series 60
16 – MBE900/4000
22
3 Speed Governor TSC1 Condition
0 – Series 60
16 – MBE900/4000
10
Eng Brk Stage 1 Off Delay Time
60 ms – Series 60
240 ms – MBE900/4000
10
Eng Brk Stage 2 Off Delay Time
60 ms – Series 60
240 ms – MBE900/4000
10
Eng Brk Stage 3 Off Delay Time
60 ms – Series 60
240 ms – MBE900/4000
10
Stage 1 Eng Brk Off Delta Spd
200 rpm – Series 60
100 rpm – MBE900/4000
10
Stage 2 Eng Brk Off Delta Spd
200 rpm – Series 60
100 rpm – MBE900/4000
10
Stage 3 Eng Brk Off Delta Spd
200 rpm – Series 60
100 rpm – MBE900/4000
10
Eng Brk Driveline Clsd Spd
Series 60 – 800 rpm
MBE 900/4000 – 800 rpm
Table 5-87
ZF Astronic Transmission Parameters
5-158
All information subject to change without notice.
(Rev. 01/07)
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION