8525-0380-0M Rev B
y
WPB Owner’s Manual
Model WPB Series
Waterproof General
Bench Scale
Owner’s Manual
Page 1: ...8525 0380 0M Rev B y WPB Owner s Manual Model WPB Series Waterproof General Bench Scale Owner s Manual ...
Page 2: ...8525 0380 0M Rev B y WPB Owner s Manual ...
Page 3: ... computing device pursuant to Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment The operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference You may find the booklet How to ...
Page 4: ...9 Clear Tare Weight Page 9 Change the Weighing Units Page 9 CHECK WEIGHING Page 10 Setting the Upper and Lower Limit Weights Page 10 CHECK WEIGHING OPERATION Page 12 CONFIGURATION Page 13 SCALE CALIBRATION Page 15 ERROR AND OPERATION DISPLAYS Page 16 BEFORE YOU CALL SERVICE Page 16 CARE AND MAINTENANCE Page 17 PRECAUTIONS Before using this instrument read this manual and pay special attention to a...
Page 5: ... WPB 30 and WPB 65 SPECIFICATIONS Model WPB 12 WPB 30 WPB 65 Capacity and Division Value 3 kg x 1 g 6 kg x 2 g 6 lb x 0 05 oz 12 lb x 0 1 oz 6 kg x 2 g 15 kg x 5 g 12 lb x 0 1 oz 30 lb x 0 2 oz 15 kg x 5 g 30 kg x 10 g 30 lb x 0 2 oz 65 lb x 0 5 oz Weight Display Six digit seven segment LED 0 56 inch 14 mm high Functions Dual Range Weight Counting Check Weighing Keys ON OFF TARE ZERO CHECK WEIGHIN...
Page 6: ...perature changes which may result in unstable weight readings Electrical Power The Model WPB Series Waterproof General Bench Scale has been designed to operate from 120V AC 50 60Hz with a US plug The socket outlet supplying power to the scale should be near the scale and should be easily accessible Ensure that the scale has good clean AC power and is properly grounded In areas subject to lightning...
Page 7: ...any damages or losses incurred during transit Placement Place the scale on a stable vibration free table stand or cart Make certain the AC power cord is routed out of the way of normal traffic DO NOT place the scale on an unstable table stand or cart The scale may fall causing injury to the operator and seriously damage the unit or proper operation of the scale may be inhibited Level Adjustment Re...
Page 8: ...opening located in the bottom of the scale To gain access to the power cord 1 Turn the scale over so that the feet are facing up 2 Locate and remove the four 4 screws securing the cover to the scale 3 Remove the power cord from the opening and route it out the side of the scale placing it in the notch of the opening ...
Page 9: ...te for up to 20 hours of continuous use with a fully charged battery Battery Charging To recharge the battery the AC power cord must be connected to an AC power outlet and plugged into the scale It will take approximately 8 hours to fully recharge the battery in the scale While the battery is charging the scale can still be operated Charging the battery for more than 8 hours will not damage it Not...
Page 10: ...d on to indicate that the weight display is at center of zero kg This LED is turned on to indicate that the displayed weight is in kilograms lb This LED is turned on to indicate that the displayed weight is in pounds lb oz This LED is turned on to indicate that the displayed weight is in pounds and ounces R1 This LED is turned on to indicate that the displayed weight is in the first lighter weight...
Page 11: ... B Err When the battery error message is displayed the operator should plug in the AC power cord into the proper electrical outlet to recharge the battery NOTE The following LEDs are only active when Check Weighing has been enabled Hi This LED is turned on to signal that the weight is greater than the Upper Limit weight setting Ok This LED is turned on to signal that the weight is within the accep...
Page 12: ...upper limit press this key to advance to the lower limit setting set Lo SET Lo Continue this until all limit settings have been entered and then press this key to save the settings and return to the weighing mode 4 During Calibration this key is used to calibrate the Zero Point weight This is the CHECK WEIGHING key It is used to perform several functions 1 It is used to enable or disable the Check...
Page 13: ...t display will return to zero with the ZERO and STABLE LEDs turned on to indicate a stable center of zero weight condition NOTE The scale will zero the weight display until 2 of the scale capacity is reached Tare Operation Place the container e g a pan or a box on the tray allow the scale to stabilize and then press the T key The NET LED will turn on Note that when removing the container from the ...
Page 14: ...he display showing set Hi SET HI press the 0 key 2 The display will change to show the current Upper limit with the first digit flashing 3 If the current setting is acceptable press the 0 key to save it and proceed to the lower limit setting set Lo SET Lo 4 If the current setting is not acceptable use the T key to select a new value for the first digit and then press the key to proceed to the next...
Page 15: ...sound P 0 LiM in If the weight on the scale is greater than the lower limit setting and less than the upper limit the Ok LED will turn on and the beeper will sound P 0 LiM Un If the weight on the scale is lower than the lower limit setting the Lo LED will turn on and the beeper will sound Or If the weight on the scale is greater than the upper limit setting the Hi LED will turn on and the beeper w...
Page 16: ...een enabled NOTE The functions of the LEDs and beeper are selected when setting the Upper and Lower limits Refer to the set Li SET Li Set the Check Weighing Functions setting Items that are outside the weight range over or under are identified by turning on an LED Hi for over or Lo for under and if enabled sounding the beeper Items that are within the weight range between the lower limit and upper...
Page 17: ... step through the selections and then press the T key to save the new setting and proceed to the next prompt Allowable settings for the weighing display speed are sPed s SPED S slow sPed P SPED M medium sPed f SPED F fast Anti Shaking Function 1 With the display showing and the current setting press the T key if the setting is acceptable and then proceed to the next prompt 2 Otherwise press the ke...
Page 18: ...to the save it and proceed to the next prompt Allowable settings for the power saving mode are 60 ON or 6 OFF sauE Save Configuration Settings 1 With the display showing sAuE and the current setting press the T key if the setting is acceptable to save all the settings and return to the weight display 2 Otherwise press the key to toggle the selection and press the T key to save all the settings and...
Page 19: ...bration switch 3 Move the calibration switch to the right as shown in the right image above 4 Return the scale to the upright position 5 Press and hold the T key and then press the ቄ key to turn the scale on 6 The scale will perform a display test and then change to show on the display with all the LEDs turned on 7 With the scale tray empty press the 0 key This will set the zero weight of the scal...
Page 20: ...uide below before you call for service The following describes several types of problems along with suggested solutions Problem Possible Solution The scale does not turn on AC Operation x Is the AC power cord fully inserted into the wall receptacle x Check wall receptacle for proper AC power Try another electrical appliance in the same receptacle Does it work x Check the circuit breaker x Has ther...
Page 21: ...e the scale in front of heating cooling vents x DO clean the scale with a damp soft cloth and mild non abrasive detergent x DO clean the scale by submerging in a dishpan and using a mild non abrasive detergent x DO make sure the cover on the bottom of the scale is installed before submerging the scale in the dishpan x DO remove AC power before cleaning with a damp cloth or submerging scale in a di...
Page 22: ...ing for the freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not include replacement of expendable or consumable parts This does not apply to any item which has deteriorated or damaged due to wear accident misuse abuse improper line voltage overloading theft l...
Page 23: ...nection with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or contract Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured The foregoing...
Page 24: ...Series Owner s Manual 20 Cardinal Scale Manufacturing Co 102 E Daugherty Webb City MO 64870 USA Ph 417 673 4631 or 1 800 641 2008 Fax 417 673 2153 Technical Support 1 866 254 8261 E mail tech cardet com 8525 0380 0M Rev B 10 20 ...