background image

 

DeTech        

1

                                                                 GateWL  REV: 02/08/2018 

 

GATE WL

 

Double tented technology via 

bidirectional radio 

 

Gate WL is a double tented technology sensor, with a 140° x 
15° coverage. Ideal for the protection of gaps, doors, 
windows, corridors and balconies.  

Caratteristiche tecniche 

 

Absorption at rest: 26 uA. 

 

Installation height: up to 4 m. 

 

Adjustable range. 

 

Adjustable relevation sensibility. 

 

Microstrip microwave 10.525 gHz. 

 

Flicker-free board 

 

Sealed optical. 

 

140° x 15° for 4 m coverage 

 

Power supply: 3,6v- n.1 lithium battery ,3v6 mod. ER14505 
cabled AA 2,4Ah. 

 

3 years of life (at standard use) 

 

Radio Freq.868MHz-FM. 

 

Encrypted code. 

 

Anti tampering protection. 

 

Radio supervision. 

 

Visual indication of low battery 

 

Selectable detection circuit.

 

 

WARNING: Before every trial, connect the 

sensor to the receiver

 

1.

 

Installation guide 

Gate WL è is designed to protect gaps like corridors, 
windows and balconies. It has to be placed horizontally in 
the middle and on the highest area of the place you need 
protection on. 

Remove the upper lid, remove the board pushing on the finger, 
carve the preprinted holes on the bottom and secure it with the 
screws and the pieces to protect with the lens pointing 
downwards. Do not point the sensor upwards. Its coverage in 
width is twice its installation height.. Ex: if placed in the middle 
of a window 1m tall, its coverage in width will 2 m.  

 

 
 

 

 

 

2.BATTERY INSERTION 

Remove the board and connect the 

battery to the circuit through the connector, positioned on the 
back of  the board and put it in the battery carrier on the D 
bottom. Wait 2 minutes for the auto-calibration. The GREEN and 
RED LEDs will blink alternatively 

3. ACQUISITION 

The acquisition of the sensor  in the system 

takes place when a Tamper alarm is generated (by releasing the 
Tamper button) 

or setting the battery in “acquisition” mode

 

4RADIO COVERAGE TEST 

When the battery is disconnected,  

push the Tamper button and connectthe battery. When the LED 
will blink, drop the Tamper button. The GREEN LED suggests a 
good signaling, when the GREEN and RED LEDs blink, the wireless 
signal is not fit, with no blinking the signal is absent. To end the 
Test, push the Tamper or wait for 4 minutes. 

5. 

ADJUSTMENT 

Adjust the range of the microwave  through the dedicated 
trimmer. Select, if necessary, the high sensitivity  relevation 
mode for open gaps that can be crossed on the run ( sens jumper 
inserted) To disable, if requested, the LED display,insert the LED 
jumper. Close the lid, hooking it on the battery side, and closing 
it with a screw. Once the lid is closed, the TAMPER will activate; 
The validation of the correct closure of the tamper is given by an 
alternating blinking (lasting for a couple of seconds) of the 
GREEN and RED LEDs. Repeat this operation if necessary. 

WARNING: Before every trial, connect the 

sensor to the receiver

 

6.      WALK TEST 

Antenna 

Finger 

 

Tamper 

Trimmer regulation MW

 

Reviews: