PRO COMPACT & CAD D300 v2.4
Page 17
3) Stopping the watermaker: without rinsing of the membranes
It is not necessary to rinse your membranes if you use your watermaker regularly.
Follow the procedure below:
Ø
Set switch to "OFF" or press
on the Mini Remote Control press (
which is
optional, see procedure in paragraph 5
).
Ø
Lower the pressure by turning the pressure regulating dial
to the left
(counterclockwise) until the needle of the high-pressure gauge
reaches its
minimum.
Ø
Once the dial cannot be turned further, reopen the pressure regulating dial by a
¼ of a turn (to the right).
Beyond 10 days without use,
it is best to rinse the membranes before the watermaker is
started-up again (see manual rinse procedure in
Appendix A3
).
The rinsing procedure should be performed every month.
If you’re not going to use the watermaker at all, the membranes must be sterilized for
storage (for a maximum period of 6 months).