Desoutter 3747 Product Instructions Download Page 10

Trouble-shooting

EN

10 / 12

06/2020

Trouble-shooting

Description

Solution

1 blink every 5 seconds.

There is no battery pack plugged on the
connector.
The battery pack is not plugged in cor-
rectly.

Plug a battery pack.
Remove the battery pack and plug it
again.

Description

Solution

Yellow - 1 blink

Temperature is below operating range
for charging.

Operate within the operating tempera-
ture of charge for the charger and the
battery pack.

Yellow - 2 blinks

Temperature is above operating range
for charging.

Let the battery pack cool down to bring
it back to operating temperature and the
error will stop.

Red - 1 blink

Battery pack is overcharged, voltage is
higher than accepted range for charging.
Charging will not start.

Leave the battery pack to rest for a cer-
tain period of time (around 5 days). 
Try again with another charger.
If the error still occurs, the battery pack
must be disposed of.

Red - 2 blinks

Charger cannot retrieve information
from battery pack temperature.
Charging will not start.

Try again with another charger.
If the error still occurs, the battery pack
must be disposed of.

Red - 3 blinks

Over-current detected.
Charging will not start.

Disconnect the battery pack from the
charger and reconnect after 5 minutes.
If the same error occurs, try the battery
pack with another charger. A charger
that has this error with different battery
packs must be disposed of for safety
reasons.

Red - 4 blinks

Time for pre-charge is too long.
Charging is stopped.

Battery pack may have been deeply dis-
charged. Try to charge the battery pack
one more time to resume normal charge.
If the error still occurs it means that the
battery pack chemistry is not working
properly anymore and so it should be
disposed of for safety reasons.

Red - 5 blinks

Time to charge is too long,
Charging is stopped.

Check plugging of the battery pack on
the charger. Poor connection between
charger and battery pack terminals may
slow down the charge.

Red - 7 blinks

Cells imbalance is out of range. Charg-
ing will not start.

It is generally due to natural cells aging
or is the consequence of repetitive
strong discharge.
Try again with another charger.
If the error still occurs, the battery pack
must be disposed of.

Red - 8 blinks

Charger cannot communicate with bat-
tery pack or the battery pack is not rec-
ognized as compatible.

Check the compatibility of the battery
pack with charger and try again with an-
other charger.
If compatible then it means that the
electronic has been damaged and then
for safety reasons the battery pack must
be disposed of.

Summary of Contents for 3747

Page 1: ...pack charger 18 36V 6158132700 Download the latest version of this document at http www desouttertools com info 6159925330_EN WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference ...

Page 2: ...arts 3 Dimensions 3 CAD files 4 Overview 4 Description 4 Technical data 4 Installation 6 Installation Instructions 6 Mounting instructions 6 Powering on 6 Operation 8 Operating Instructions 8 How to charge a battery pack 8 Charging time 8 Service 9 Maintenance Instructions 9 Maintenance instructions 9 Trouble shooting 10 ...

Page 3: ...tenance typical for that period expressed in time operation hours or otherwise The product warranty relies on the correct use maintenance and repair of the tool and its component parts Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Desoutter or their Certified Service Partners during the warranty period is not covered by the warranty To avoid d...

Page 4: ...ta Power supply Input voltage 100 240 V AC Frequency 50 60 Hz Maximum input current single 2 A daisy chain 6 3 A Output voltage 0 42 V DC Output current 2 A Maximum number of chargers connected in daisy chain 10 VIN 230 V AC 5 VIN 115 V AC Weight 0 665 kg 1 47 lb Storage and use conditions Storage temperature 20 to 70 C 4 to 158 F Operating temperature 0 to 45 C 32 to 113 F Storage humidity 0 95 R...

Page 5: ...EN Product Information 06 2020 5 12 Indoor use only ...

Page 6: ...follows Use M5 screws not supplied Daisy chain connection Daisy chain connection Refer to the chapter Technical data Page 4 to know how many chargers can be daisy chained For example 1 Daisy chain the chargers as shown above Use the optional dedicated cable length 30 cm 11 81 in part number 6158133830 2 Plug the last charger to the mains Powering on Use the following power cords to power supply th...

Page 7: ... 2 ft 6159172030 UK 2 5 m 8 2 ft 6159172020 China 2 5 m 8 2 ft 6159172060 Use only the power cord supplied 1 Plug for power cord Connect the power cord to the charger and plug it to the mains The 4 white LEDs light up and then go out The warning LED lights up in red turns orange and then goes out ...

Page 8: ...harge level LED 1 starts blinking 0 24 LED 2 starts blinking LED 1 is steady 25 49 LED 3 starts blinking LED 1 and 2 are steady 50 74 LED 4 starts blinking LED 1 2 and 3 are steady 75 100 When there is no battery pack on the charger LED 4 blinks every 5 seconds Special precautions for charging batteries WARNING Risk of injury Only charge Li ion type rechargeable battery pack Other types of batteri...

Page 9: ...the manufacturer or authorized service providers If one of the following situations arises get the charger checked by the manufacturer or authorized service providers a The power cord or plug is damaged b Liquid has penetrated into the charger c The charger has been exposed to moisture d The charger does not work well or you cannot get it to work according to the user s manual e The charger has be...

Page 10: ...he battery pack from the charger and reconnect after 5 minutes If the same error occurs try the battery pack with another charger A charger that has this error with different battery packs must be disposed of for safety reasons Red 4 blinks Time for pre charge is too long Charging is stopped Battery pack may have been deeply dis charged Try to charge the battery pack one more time to resume normal...

Page 11: ...y 5 seconds Battery pack is strongly discharged and cannot be charged anymore for safety reasons For charger rev1 it can also be a communication issue or compatibil ity issue red 8 blinks Try again with another charger If the error still occurs the battery pack must be disposed of ...

Page 12: ...icles Off Road General Industry Desoutter offers a comprehensive range of Solutions tools service and projects to meet the specific demands of local and global customers in over 170 countries The company designs develops and delivers innovative quality industrial tool solutions including Air and Electric Screwdrivers Advanced Assembly Tools Advanced Drilling Units Air Motors and Torque Measurement...

Reviews: