4
Contents:
1.
Technical characteristics
4.
Operation
2.
Description
5.
Warranty
3.
Installation
6.
Recycling
7.
Compliance
1.
Technical characteristics
Power supply: 230V/1/50Hz /60Hz
NTC sensor 3m long
Dry contact: 12A motor
IP X4
Power consumed: 4,5W
Temperature range: -50°C /+110°C
2.
Description
JD HORS GEL allows the filter pump to start in forced mode when the outside air temperature is equal to or lower than the set
temperature.
CAUTION: JD HORS GEL does not have priority on the filtration control panel. So in 'manual' filtering mode or 'automatic' mode during
programming times, the filter pump runs regardless of the outside temperature.
3.
Installation
Position the unit so that the sensor can measure an air temperature as 'real' as possible. Do not place the sensor near a source of heat
or radiation. JD HORS GEL must be connected to the filtration panel in accordance with the diagram at the end of the guide. JD Hors
Gel must be installed
at a minimum distance from the end of the pool, defined with reference to the national electrical standards that
apply in the countryof installation. In France, standard NF C 15 100 (section 702) specifies that this appliance, potentially subject to
water splashes, must be installed over 3.5 metres away from any pool or water supply
4.
Operation
•
Description
.
•
Adjusting the set point
Press SET for 1 sec. to display SET, then validate with SET again.
Modify the value with
or
.
Press
to confirm and
to return to the temperature.
The setpoint is factory set to 6°C. This can be changed as described above. The filtration pump starts when the measured temperature
is equal to or lower than the setpoint. It stops when the measured temperature is equal to the set value + 1° C. LED 1 indicates that
the filtration pump is operating in forced mode.
CAUTION: If you find that your filter runs continuously during the summer periods, please check the
value of the setpoint.
•
Error codes / Malfunction
SYMBOL
PROBLEM
OBSERVATION
+ CODE E1
DEFECTIVE SENSOR
Replace the sensor.
The device automatically switches to 'safety' operating
mode with the
pump forced to run 24 hours/day
.
Random temperature display or black screen
BOARD FAULT
Replace the board.
5.
Warranty
JD HORS GEL is guaranteed 12 months (parts) from the date of the sales invoice.
Any defects or damage arising from improper installation and / or use are excluded from the warranty. The warranty is excluded if
the circuit board has been opened or the internal programmes of the board modified
6.
Recycling
When the unit reaches the end of its operating life, do not throw it in the waste bin. This symbol means that the object will be
collected for reuse, recycling or recovery. Contact your dealer for further information.
7.
Compliance with standards
JD HORS GEL complies with the European standards and directives in force: Electrical safety 2006/95/EC, 2004/108/EC; Electrical
compatibility, ROHS.
E
N
G
L
IS
H
Back to previous display
Displays the setpoint and validates
its value.
Browse or increase the parameter value
Browse or decrease the parameter value