background image

                                                                                                                   

 

This Manual is applicable to the  De Sisti F4.7 Vari-White 

 

Revised on July 2018 

ILT ITALY srl 

Via Cancelliera, 10/a  
00041 Albano Laziale (Rome) Italy 
tel. +39 06-902901 fax +39 06-90231051 
www.desisti.it 

 

9. 

PERIODIC INSPECTION & MAINTENANCE 

This product requires very little routine maintenance, if any, but has special cleaning instructions: 

Disconnect fixture from power and allow it to cool for 10 min. 

1.

 

Vacuum or gently blow away any dust from fan blades and grills 

2.

 

Very gently clean the LED with Isopropyl alcohol. 

3.

 

Clean the lenses with a soft damp cloth. 

4.

 

Check the condition of the safety shield (see chapter: Installation Instructions) before every use. 

5.

 

Check Power supply cable and DMX control cable proper conditions 

 

10. 

SAFETY STANDARDS

 

Europe: The product conforms the Applicable European Directives & Standards 

Low Voltage Directive: 

73/23/EEC (as amended by 93/68/EEC) 

EMC Directive: 

89/336/EEC (as amended by 92/31/EEC & by 93/68/EEC) 

Europen Standards:: 

EN 60598-2-17, EN 60598-1 , EN 55015 , EN 61547 

 

Disposing of this product: 

Help preserve the environment! Ensure that this product is recycled at the end of its life. 

This product is in compliance with the RoHS and WEEE directives. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SUPER LED F14

Page 1: ...ns you can depend upon the quality of this product The SUPER LED F14 is a compact highly efficient Fresnel lens spotlight using a LED ARRAY combined with the DE SISTI Patented optical system to optimi...

Page 2: ...AND PERFORMANCE DATA DESCRIPTION VALUE DESCRIPTION VALUE LED Power 400 W Protection Type IP22 Power Consumption 490 W 230V 50 60 Hz Max Housing temperature 70 C 490 W 120V 50 60 Hz DMX Data Link USIT...

Page 3: ...ected to the connection point marked with the letter L or colored in red Working conditions Working Position Lighting fixture max tilting 90 from horizontal Ambient temperature ta at the place of inst...

Page 4: ...of 0 1m 4 in around fans and air vents Shields lenses safety or dichroic glasses shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired for example...

Page 5: ...l go in STAND BY Mode It will go ON again anytime a KNOB is activated KNOB 2 It is as a DEFAULT the DIMMING Variation Knob By rotating it clockwise the Dimming of the Light Changes from 0up to Full Li...

Page 6: ...again This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming plus CCT level can be blocked so that for instance a system lighting a SET can be operated by a remote switch or simple...

Page 7: ...it INFORMATION PROVIDED ON THE DISPLAY 8 DIMENSIONS Dimensions Black mm Red inches Dimensions Black mm Red inches Display of Correlated Colour Temperature Display of LED Case TEMPERATURE Display of D...

Page 8: ...D with Isopropyl alcohol 3 Clean the lenses with a soft damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX...