installation instructions

[email protected]

www.designplan.com

P:  908-996-7710

F:  

 

908-996-7042

 

2 of 

5

STEP OUTSIDE 5.1, 5.2, 6.1, 6.2, 6.3

3.42"

Ø

4.21"

Ø

1.85"

NO

NO

OK

2

1

Outer casing plug

Position flush to the 

finished floor!

Housing Installation (WC1501)

Use 

7-12

” of drainage gravel - check functionality: fill tube with water and verify full drainage within 30 min.  If water 

remains, please utilize a different drainage system that functions properly.  Contractor to seal the conduit with “Great 
Stuff” aerosol 

seal

 that prevents water and moisture penetration for ultimate protection.

It is the contractor's responsibility to

install Remote Driver in a suitable

electrical enclosure.

TM

Summary of Contents for STEP OUTSIDE 5.1

Page 1: ...liance class and type of use It must include the following operations Periodically clean fixtures to remove dirt from gratings and screw heads Check tightness of screws on various parts of the device Check that all cable glands and cables are intact and tight Check that the glass or plastic lens is intact and replace it if broken or damaged The internal components such as the ballast driver washer...

Page 2: ...sh to the finished floor Housing Installation WC1501 Use 7 12 of drainage gravel check functionality fill tube with water and verify full drainage within 30 min If water remains please utilize a different drainage system that functions properly Contractor to seal the conduit with Great Stuff aerosol seal that prevents water and moisture penetration for ultimate protection It is the contractor s re...

Page 3: ...wise rotation 5 6 Overall dimensions 4 WC1501 WC1501 4 max 500mA Package Contents STEP 5 1 STEP 5 2 STEP 6 1 STEP 6 2 STEP 6 3 Use corrugated conduit Ø20 minimum recommended Ø25 Use corrugated conduit Ø20 minimum recommended Ø25 Ø 1 77 2 Ø16mm Ø16 x 70 mm 0 63 x 7 09 min 0 197 max 1 18 Ø1 77 1 Use corrugated conduit Ø20 minimum recommended Ø25 2nd 2 Use gel filled waterproof wire nuts for wire con...

Page 4: ... 996 7710 F 908 996 7042 4 of 5 STEP OUTSIDE 5 1 5 2 6 1 6 2 6 3 Ø2 0 3 0 PPMP03113 In Grade Housing Installation PPMP03113 Drill pilot hole for core drilled housing through wall Connect to driver and install fixture Apply epoxy to sides of newly drilled opening insert core drilled housing into pilot hole and make level POSITON FLUSH WITH THE WALL ...

Page 5: ...consumption Only power up the system once all the lamps are connected Connecting an individual lamp to an active power supply may cause the lamp to break due to over voltage The electronic power supply is constant current so to a certain extent it automatically compensates the voltage drop associated with cable length however we advise not exceeding 100 feet Lamps and power supply units must be in...

Reviews: