background image

www.desatech.com

111161-01H

8

ILLUSTRATED PARTS bREAkDOWN

MODELS CCL3018PR, CCL3018PRA, CCL3018NR AND CCL3018NRA

9

23

25

24

23

21

12

11

14

4

5

1

2

18

10

13

30

22

6

3

8

20

7

15

16

17

17

28

28

27

26

29

19

 

F
 

 

P

IL

  

 

N

 

 

  

  

   

   

 

 
 

 
 

 

 

 

 

 

 
 

 

 

 

  

 

 

 

  

  

   

   

 

 

 
 
 

 

 

 

 

 

 

 

 

Note:

 Items 

16 and 1 
are Natural 
Gas only.

Summary of Contents for Yellow Flame CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA, CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA, CHL3924NR, CHL3924PR, C

Page 1: ...Refractory Brick liners or firebrick panels Glass doors or replacement glass Replacement logs for gas log sets stoves or fireplaces Information about DESA International In December 2008 Desa internat...

Page 2: ...ow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplie...

Page 3: ...28 Illustrated Parts Breakdown MODELS CCL3018PR CCL3018PRA CCL3018NR and CCL3018NRA 9 23 25 24 23 21 12 11 14 4 5 1 2 18 10 13 30 22 6 3 8 20 7 15 16 17 17 28 28 27 26 29 19 F P I L N Note Items 16 a...

Page 4: ...er 1 15 100609 01 100609 01 099387 13 099387 13 Pilot Tube 1 16 ____ ____ 099918 02 099918 02 Pilot Regulator 1 17 ____ ____ 099387 15 099387 15 Pilot Tube Valve to regula tor 1 18 103345 02 103345 02...

Page 5: ...4 5 1 2 17 10 21 20 22 6 7 3 9 20 16 8 15 29 28 28 25 26 P I N H 24 31 13 Illustrated Parts Breakdown MODELS CCL3924PR CCL3924PRA CCL3924NR CCL3924NRA CCL3930PR CCL3930PRA CCL3930NR CCL3930NRA CHL3924...

Page 6: ...2 01 102772 01 102772 01 Burner 1 15 099387 09 099387 12 099387 09 099387 12 Pilot Tube 1 16 103781 02 103781 02 103781 02 Gas Control Valve LP 1 103781 01 103781 01 Gas Control Valve NG 1 17 103345 0...

Page 7: ...e LP Ignition Piezo Manifold Pressure 8 0 W C Inlet Gas Pressure in of water Max 14 W C Min 11 W C CCL3018NR and CCL3018NRA Rating Variable 16 000 30 000 Btu Hr Type Gas Natural Ignition Piezo Manifol...

Page 8: ...y flue damper for vented operation Can be used only with non thermostat accessories RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT HRC201 For all Remote Ready Models Allows the gas log heater to...