www.desatech.com
122136-01C
17
PILOT
OFF
LO
HI
3. Press in and turn control knob clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information, page 16. If you
don’t smell gas, go to the next step.
5. Press in control knob and turn counter-
clockwise
to the PILOT position.
The ignitor will spark once. Keep control
knob pressed in for 5 seconds. If control
knob does not pop up when released,
contact a qualified service person or gas
supplier for repairs.
Note: You may be running this heater for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
6. Turn control knob clockwise
to
OFF position. Press in control knob and
turn counterclockwise
to PILOT
position. This will light pilot. Pilot is at-
tached to rear of burner. If needed, repeat
this process until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
8. Slightly press and turn control knob coun-
terclockwise
to desired heating
level. The burner should light. Set control
knob to HI or LO.
Figure 19 - Control Knob and Ignitor
Button Location
Control Knob
Figure 20 - Pilot
VARIABLE CONTROL
OpERATION
The variable control valve can be set to high
or low, by simply turning the control knob
until that setting is attained. Even the low-
est setting provides realistic, dancing yellow
flames. Selecting higher settings produces
greater heat output. This results in increased
heating comfort.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO AppLIANCE
1. Press in and turn control knob clockwise
to the OFF position.
2. Close equipment shutoff valve (see figure
15, page 14.
MANUAL LIGHTING
pROCEDURE
1. Follow steps 1 through 5 under
Lighting
Instructions
, page 16.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8
under
Lighting Instructions
, page 16.
OPERATION
Continued
Ignitor Electrode
Pilot Burner
Thermocouple
WARNING: Do not operate
heater between PILOT and HIGH
positions.
9. To leave pilot lit and shut off burners only,
turn control knob clockwise
to the
PILOT position.