1.  This appliance is only for use with the type of 

gas indicated on the rating plate. This appliance 

is not convertible for use with other gases. 

2.  Do not place propane/LP supply tank(s) in

-

side any structure. Locate propane/LP supply 

tank(s) outdoors (propane/LP units only).

3.  To prevent performance problems, do not 

use propane/LP fuel tank of less than 100 lb. 

capacity (propane/LP units only).

4.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use 

any phone in your building

• immediately call your gas supplier from a 

neighbor’s phone. Follow the gas supplier’s 

instructions

• if you cannot reach your gas supplier, call 

the fire department

5.  This heater shall not be installed in a bedroom or 

bathroom, unless installed as a vented appliance. 

See 

Installing Damper Clamp Accessory for 

Vented Operation

, page 12.

6.  Do not burn solid-fuel in a masonry or UL127 

factory-built fireplace in which a vent-free 

room heater is installed.

7.  Before installing in a solid fuel burning fireplace, 

the chimney flue and firebox must be cleaned 

of soot, creosote, ashes and loose paint by a 

qualified chimney cleaner. Creosote will ignite 

if highly heated. A dirty chimney flue may cre

-

ate and distribute soot within the house. Inspect 

chimney flue for damage. If damaged, repair flue 

and firebox before operating heater.

8.  If fireplace has glass doors, never operate this 

heater with glass doors closed. If you operate 

heater with doors closed, heat buildup inside fire

-

place will cause glass to burst. Make sure there are 

no obstructions across openings of fireplace.

9.  This log heater is designed to be smokeless. If 

logs ever appear to smoke, turn off heater and 

call a qualified service person. 

Note:

 During 

initial operation, slight smoking could occur 

due to log curing and heater burning manu

-

facturing residues. 

10.  To prevent the creation of soot, follow the instruc

-

tions in 

Cleaning and Maintenance

, page 19.

11.  Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater off. If 

heated, the vapors from these products may 

create a white powder residue within burner 

box or on adjacent walls and furniture.

SAFETy INFORMATION

Continued

12.  This heater needs fresh, outside air ventilation to 

run properly. This heater has an Oxygen Deple

-

tion Sensing (ODS) safety shutoff system. The 

ODS shuts down the heater if enough fresh air 

is not available. See 

Air for Combustion and 

Ventilation

, page 5. If heater keeps shutting 

off, see 

Troubleshooting

, page 21.

13.  Do not run heater

• where flammable liquids or vapors are used 

or stored

• under dusty conditions

14.  Do not use this heater to cook food or burn 

paper or other objects.

15.  Do not use heater if any part has been exposed 

to or under water. Immediately call a qualified 

service technician to inspect the room heater 

and to replace any part of the control system and 

any gas control which has been under water. 

16.  Do not operate heater if any log is broken. Do 

not operate heater if a log is chipped (dime-

sized or larger). 

17.  Turn heater off and let cool before servicing, 

installing or repairing. Only a qualified service 

person should install, service or repair heater.

18.  Operating heater above elevations of 4,500 

feet may cause pilot outage.

19.  Provide  adequate  clearances  around  air 

openings.

LOCAL CODES

Install and use heater with care. Follow all local 

codes. In the absence of local codes, use the lat

-

est edition of 

The National Fuel Gas Code ANSI 

Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note:

 Where listed vented decorative logs are 

required, thermostat operation is not permitted.

State  of  Massachusetts:

  The  installa-

tion must be made by a licensed plumber 

or  gas  fitter  in  the  Commonwealth  of

 

Massachusetts.
Sellers  of  unvented  propane  or  natural 

gas-fired supplemental room heaters shall 

provide to each purchaser a copy of 527 

CMR 30 upon sale of the unit.
Vent-free  gas  products  are  prohibited  for 

bedroom  and  bathroom  installation  in  the 

Commonwealth of Massachusetts.

Summary of Contents for SGS3124N

Page 1: ...o not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WINCHESTE...

Page 2: ... 5 Installation 8 Operating Heater 17 Inspecting Burners 19 Cleaning and Maintenance 19 Technical Service 20 Service Hints 20 Troubleshooting 21 Specifications 24 Replacement Parts 24 Accessories 24 Parts Centrals 25 Illustrated Parts Breakdown and Parts List 26 Warranty Information Back Cover WARNING Improper in stallation adjustment al teration service or main tenance can cause injury or propert...

Page 3: ...ugh no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this heater safety information Continued WARNING Donotallowfans to blow d...

Page 4: ...ore using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture safety information Continued 12 Thisheaterneedsfresh outsideairventilationto run properly This heater has an Oxygen Deple tion Sensing ODS safety shutoff system The ODS shuts down the heater...

Page 5: ... This heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air Piezo Ignition System This heater has a piezo ignitor This system re quires no matches batteries or other sources to light heater Air For Combustion and Ventilation WARNING This heater...

Page 6: ...of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms com municating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space...

Page 7: ... National Fuel Gas Code ANSIZ223 1 NFPA54Section5 3 or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining un confined space When ventilating to an adjoining unconfined space you must provide two permanent Figure 2 Ventilation Air from Inside Building Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Ro...

Page 8: ...lace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper WARNING Never install the heater in a bedroom or bathroom unless installed as a vented appliance see page 12 in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 from the front top or sides of the heater in high traffic areas in wind...

Page 9: ...nimum clearances to combustible materials B Clearances from the top of the fireplace opening to the ceiling should not be less than 42 Installation Continued Figure 4 Minimum Clearance for Combustible to Wall Minimum 16 from Side Wall Example NOTICE Manualcontrolheaters maybeusedasaventedproduct Ifso youmustalwaysrunheater with chimney flue damper open If running heater with damper open noncombust...

Page 10: ...mper open Mantel Clearances In addition to meeting noncombustible material clearances you must also meet required clearances between fireplace opening and mantel shelf If you do not meet the clearances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top of fireplace opening a hood is not required see Figure 6 page 11 Det...

Page 11: ...ial 8 Min 12 15 18 All minimum distances are in inches Log Set 18 and 24 Models 20 2 1 2 6 8 10 12 Distances to Underside of Mantel Hood GA6050 GA6052 Top of Fireplace Opening Underside of Mantel Shelf Mantel Shelf Figure 6 Minimum Mantel Clearances Without Using Hood Figure 9 Minimum Fireplace Clearances Above Combustible Flooring Figure 7 Minimum Mantel Clearances When Using Hood Figure 8 Minimu...

Page 12: ...flue opening you must provide Attach damper clamp so the minimum permanent flue opening will be maintained at all times Chimney Minimum Permanent Height Flue Opening 6 to 15 39 sq inches 15 to 30 29 sq inches Area of Various Standard Round Flues Diameter Area 5 20 sq inches 6 29 sq inches 7 39 sq inches 8 51 sq inches Figure 10 Attaching Damper Clamp INSTALLING HEATER BASE ASSEMBLY CAUTION Donotre...

Page 13: ...ater base 7 Mark screw locations through holes in mount ing brackets see Figure 12 If installing in a brick bottom fireplace mark screw locations in mortar joint of bricks 8 Remove heater base from fireplace 9 Drill holes at marked locations using 3 16 drill bit 10 Attach base assembly to fireplace floor using two masonry screws in hardware package see Figure 12 Figure 12 Attaching Base Assembly t...

Page 14: ...t Pointing Down within reach for test gauge hook up NPT tap must be upstream from heater see Figure 14 IMPORTANT Installequipmentshutoffvalveinan accessible location The main gas valve is for turn ing on or shutting off the gas to the appliance Checkyourbuildingcodesforanyspecialrequirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male NPT threads Thi...

Page 15: ...rect all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 15 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using...

Page 16: ...ll these logs exactly as instructed Do not modify logs Only use logs supplied with heater 1 Locate pegs on the bottom of back log 1 Slide these pegs into the holes in the grate base behind the burner see Figure 18 2 Locate the notches on the back of the front log 2 Slide these notches over the tabs of the grate base see Figure 19 3 Locate the notches in the bottom of the crossover log 3 Place the ...

Page 17: ...y part of the control system and any gas control which has been under water lighting instructions WARNING If fireplace has glass doors never operate this heater with glass doors closed If you op erateheaterwithdoorsclosed heat buildup inside fireplace willcauseglasstoburst Make suretherearenoobstructions across openings of fireplace You must operate this heater with a fireplace screen in place Mak...

Page 18: ...I and LO CAUTION Do not operate heater between PILOT and HI positions VARIABLE CONTROL OPERATION The variable control valve can be set to any heat setting and flame height desired by simply turning the control knob until that setting is attained Even the lowest setting provides re alistic dancing yellow flames Selecting higher settings produces greater heat output This results in increased heating...

Page 19: ...r inspected yearly by a qualified service person Heater may need more frequent clean ing due to excessive lint from carpeting bedding material pet hair etc WARNING Failure to keep the primary air opening s of theburner s cleanmayresultin sooting and property damage ODS PILOT AND BURNER Use a vacuum cleaner or small soft bristled brush to clean Burner Injector Holder and Pilot Air Inlet Hole The pr...

Page 20: ...vailable LOGS If you remove logs for cleaning refer to Install ing Logs page 16 to properly replace logs Replace log s if broken or chipped dime sized or larger BURNER PRIMARY AIR HOLES Air is drawn into the burner through the 8 holes in the brass fitting at the entrance to the burner These holes may become blocked with dust or lint Periodically inspect these holes for any blockage and clean as ne...

Page 21: ...ogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Control valve damaged OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by ...

Page 22: ...blem will stop after a few hours of operation 1 Refer to Air for Combustion and Ventilation requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 9 4 Clean burner see Cleaning and Maintenance page 19 or rep...

Page 23: ... using odor caus ing products while heater is running 2 Refill supply tank propane LP only 3 Locate and correct all leaks see Checking Gas Connec tions page 15 1 Open window and or door for ventilation 2 Contact local natural or pro pane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 19 1 Locate and correct all leaks see Checking Gas Connec tions page 15 2 Replace control valve...

Page 24: ...rs of this product If they can t supply original replacement part s call DESA Heating Products at 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number Accessories Purchase these fireplace accessories from your local dealer Iftheycannotsupplytheseaccessories either contactyournearestPartsCentralorcallDESAHeat i...

Page 25: ...s Street Bowling Green KY 42103 3414 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy 10 East Route 36 W Long Branch NJ 07764 732 870 8809 1 800 755 8809 www...

Page 26: ...ch com 107068 01K 26 Illustrated Parts Breakdown Variable Manually Controlled Winchester Oak Models SGS3124N and SGS3124P 4 2 1 3 12 21 10 11 21 7 21 5 8 9 15 14 16 19 6 18 13 19 17 20 18 Natural Gas Pilot Shown ...

Page 27: ... 01 Inlet Tube 1 10 099056 18 099056 19 Burner Orifice Injector 1 11 111124 01 111124 01 Burner Retainer Spring 1 12 102773 01 102773 01 Burner 1 13 102568 07 102568 08 Control Valve 1 14 098508 01 098508 01 Valve Retainer Nut 1 15 098354 01 098354 01 Control Knob 1 16 102445 01 102445 01 Piezo Ignitor 1 17 098249 01 098249 01 Nut M5 2 18 099387 08 099387 08 Pilot Tube 1 19 098271 10 098271 10 Ign...

Page 28: ...of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED...