OWNER’S MANUAL

Figure 20 - Incorrect Pilot Flame Pattern

Thermocouple

Pilot Burner

INSPECTING
BURNER

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pattern.
Figure 20 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touch-
ing the thermocouple. This will cause the
thermocouple to cool. When the thermo-
couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 20

• turn heater off (see To Turn Off Gas to Ap-

pliance, page 12)

• see Troubleshooting, pages 14 through 16

BURNER FLAME PATTERN

Figure 19 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Figure 21 shows a correct burner flame
pattern. Figure 22 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.

If burner flame pattern is incorrect, as shown
in Figure 22

• turn heater off (see To Turn Off Gas To Ap-

pliance, page 12)

• see Troubleshooting, pages 14 through 16

1/2 G

Figure 21 - Correct Burner Flame Pattern

Yellow Tipping

1/2 G

Figure 22 - Incorrect Burner Flame Pattern

NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
heater and burn causing brief
patches of orange flame.

 WARNING: If yellow tipping

occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pattern
shows yellow tipping, follow in-
structions at bottom of this page.

CLEANING AND
MAINTENANCE

 WARNING: Turn off heater

and let cool before cleaning.

 CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

1

/

2

 Wind

Shield
Height

1

/

2

 Wind

Shield
Height

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air,

or small, soft bristled brush to clean.

CLEANING BURNER
PILOT AIR INLET HOLE

We recommend that you clean the unit every
2,500 hours of operation or every three months.

We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store, or
home center may carry compressed air in a
can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can,  you
could damage the pilot assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot for dust and dirt.

3.

Blow air through the ports/slots and
holes in the burner.

Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 23). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.

Figure 23 - Pilot Inlet Air Hole

Pilot Assembly

Pilot Air Inlet
Hole

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

Summary of Contents for Glo-Warm FGHS30LPB

Page 1: ... be performed by aqualifiedinstaller serviceagency orthegas supplier Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This is an unvented gas fired heater It uses air oxy gen from the room in which it is installed Provisions for ad equate combustion and ventila tion air must be provided Refer to Air For Combustion and Ven tilation section on page 4 of this man...

Page 2: ...resh outside air ven tilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 6 Keep all air openings in front and bot tom of heater clear and free of debris This will insure enough air for proper combustion 7 If heater shuts off do not r...

Page 3: ... If heater is damaged promptly inform dealer where you bought heater Figure 1 Vent Free Propane LP Gas Heater Ignitor Button Control Knob Heater Cabinet Front Panel PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is not enough ...

Page 4: ...n and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6x10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added o...

Page 5: ...t include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 70 000 Btu Hr actual amount of Btu H...

Page 6: ...heatticwillactivatethepowervent AIR FOR COMBUSTION AND VENTILATION Continued Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 12 12 Ventilation Grills into Adjoining Room Option 1 VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide tw...

Page 7: ...uch moisture See Air for Com bustion and Ventilation pages 4 through 6 CAUTION Thisheatercreates warmaircurrents Thesecurrents moveheattowallsurfacesnextto heater Installing heater next to vinyl or cloth wall coverings or operatingheaterwhereimpurities suchastobaccosmoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls WARNING Never install the heater ...

Page 8: ...cket Removing Front Panel Of Heater 1 Remove two screws near bottom cor ners of front panel 2 Liftstraightupongrillguarduntilitstops Grill guard will slide up about 1 4 3 Pull bottom of front panel forward then down 4 Remove cardboard packing from grill and glass INSTALLATION Continued Marking Screw Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket i...

Page 9: ...l mounting bracket is firmly fastened to wall Figure 9 Folding Anchor INSTALLATION Continued Placing Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater 2 Place heater onto mounting bracket Slide horizontal slots onto stand out tabs on mounting bracket see Figure 11 Figure 12 Installing Bottom Mounting Screws Figure 10 Popping Open Anchor Wings For Thin Walls Figure 11...

Page 10: ...all the external regu lator between the heater and propane LP supply Typical Inlet Pipe Diameters FGHS30LPB 1 2 or greater Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 14 CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used i...

Page 11: ...nob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to thermostat gas valve see Fig ure 16 Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 11 and 12 Check all other in ternal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 12 8 Replace fr...

Page 12: ... Pilot Note If pilot goes out repeat steps 3 through 7 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise C clockwise to desired heating level The main burner should light Set control knob to any heat level between HI and LO Thermocouple Ignitor Electrode Pilot Burner OPERATING HEATER Continued PILOT L O OFF H I LIGHTING INS...

Page 13: ...rol areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc 1 2 Wind Shield Height 1 2 Wind Shield Height ODS PILOT AND BURNER Use a vacuum cleaner pressurized air or small soft bristled ...

Page 14: ... Dirty or partially clogged ODS pilot 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace piezo ignitor 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while...

Page 15: ...blem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clear ances see Figure 4 page 7 4 Clean burner see Cleaning and Mainte nance page 13 or replace burner orifice 1 Turn heater off when using furniture polish...

Page 16: ...g statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF posit...

Page 17: ... 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 www njplaza com ...

Page 18: ...BLUE FLAME PROPANE LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODEL FGHS30LPB 7 7 5 2 5 27 22 26 23 19 17 24 25 12 26 21 20 18 9 8 18 16 10 16 13 1 14 14 15 7 6 11 3 7 4 7 7 24 1 24 2 ODS Pilot Assembly ...

Page 19: ...11 01 Ignitor Line 1 13 L99029 04 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98115 03 Main Inlet Tube Assembly 1 17 L98123 06 ODS Line Assembly 1 18 L98126 01 Burner Inlet Tube Assembly 1 19 L98506 01 Burner 1 20 L98507 01 Burner Connector 1 21 L98508 02 Injector 1 22 L98504 01 Left Burner Support Bracket 1 23 L98505 01 Right Burner Support Bracket 1 24 L98071...

Page 20: ...will not produce specified heat propane LP gas supply may be low When Gas Quality Is Bad pilot will not stay lit burner will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your local propane LP gas supplier SERVICE PUBLICATIONS You can purchase service manual from the address listed on the back page of this manual Send a c...

Page 21: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Page 22: ...The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost lab...

Reviews: