NATURAL GAS HEATER

AIR FOR
COMBUSTION AND
VENTILATION

Today’s homes are built more energy effi-
cient than ever. New materials, increased
insulation, and new construction methods
help reduce heat loss in homes. Home owners
weather strip and caulk around windows and
doors to keep the cold air out and the warm air
in. During heating months, home owners
want their homes as airtight as possible.

While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning
appliances need fresh air for proper com-
bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and
fuel burning appliances draw air from the
house to operate. You must provide ad-
equate fresh air for these appliances. This
will insure proper venting of vented fuel-
burning appliances.

 WARNING: This heater shall

not be installed in a confined space
or unusually tight construction
unless provisions are provided
for adequate combustion and ven-
tilation air. Read the following in-
structions to insure proper fresh
air for this and other fuel-burning
appliances in your home.

PROVIDING ADEQUATE
VENTILATION

The following are excerpts from National
Fuel Gas Code. NFPA 54/ANS Z223.1, Sec-
tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three
following ventilation classifications:

1.

Unusually Tight Construction

2.

Unconfined Space

3.

Confined Space

The information on pages 4 through 6 will
help you classify your space and provide
adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win-
dows may provide enough fresh air for
combustion and ventilation. However, in
buildings of unusually tight construction,
you must provide additional fresh air.

Unusually tight construction is de-
fined as construction where:

a.

walls and ceilings exposed to the
outside atmosphere have a con-
tinuous water vapor retarder with
a rating of one perm (6x10

-11

 kg

per pa-sec-m

2

) or less with open-

ings gasketed or sealed 

and

b. weather stripping has been

added on openable windows and
doors 

and

c.

caulking or sealants are applied
to areas such as joints around
window and door frames, be-
tween sole plates and floors, be-
tween wall-ceiling joints, be-
tween wall panels, at penetra-
tions for plumbing, electrical, and
gas lines, and at other openings.

If your home meets all of the three
criteria above, you must provide ad-
ditional fresh air. See 

Ventilation Air

From Outdoors, page 6.

If your home does not meet all of the
three criteria above, proceed to 

De-

termining Fresh-Air Flow For Heater
Location, page 5.

Confined and Unconfined Space

The National Fuel Gas Code ANS Z223.1
defines a confined space as a space whose
volume is less than 50 cubic feet per 1,000
Btu per hour (4.8 m3 per kw) of the aggre-
gate input rating of all appliances installed
in that space and an unconfined space as a
space whose volume is not less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all
appliances installed in that space. Rooms
communicating directly with the space in
which the appliances are installed*, through
openings not furnished with doors, are con-
sidered a part of the unconfined space.

This heater shall not be installed in a con-
fined space or unusually tight construction
unless provisions are provided for adequate
combustion and ventilation air.

* Adjoining rooms are communicating only
if there are doorless passageways or ventila-
tion grills between them.

Summary of Contents for Glo-Warm FA-2B

Page 1: ...ied installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxy gen from the room in which it is installed Provisionsforadequate combustion and ventilatio...

Page 2: ...vicing Only a qualified service person should service and repair heater 12 Operating heater above elevations of 4 500 feet could cause pilot outage WARNING Any change to this heater or its controls c...

Page 3: ...tion Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If...

Page 4: ...ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to t...

Page 5: ...nt draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space...

Page 6: ...adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation...

Page 7: ...arances from floor ceiling and joining wall LOCATING HEATER This heater is designed to be mounted on a wall WARNING A qualified ser vice person must install heater Follow all local codes CHECK GAS TYP...

Page 8: ...ry drill at least 1 deep 2 Fold wall anchor as shown in Figure 8 3 Insert wall anchor wings first into hole Tap anchor flush to wall 4 For thin walls 1 2 or less insert red key into wall anchor Push r...

Page 9: ...troleum LP gas Installationmustincludeequipmentshutoff valve ground joint union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be up stream from heater see Fi...

Page 10: ...ted on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Applymixtureofliquidsoapandwaterto gas...

Page 11: ...ied service person or supplier for repairs 6 Release downward pressure on con trol knob and turn clockwise to OFF position 7 Press in control knob and turn back to PILOT IGN This will cause the piezo...

Page 12: ...Use a vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit every 2 500hoursofoperationoreverythreemonths Weals...

Page 13: ...5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or part...

Page 14: ...ar products TROUBLESHOOTING Continued OBSERVED PROBLEM Burner s does not light after ODS pilot is lit Delayed ignition of burner s Burner backfiring during combustion Burner plaque s does not glow Sli...

Page 15: ...r burning vapors from paint hair spray glues etc see IMPORTANT statement above 2 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is par...

Page 16: ...nternational When Gas Pressure Is Too Low pilot will not stay lit burner s will have delayed ignition heater will not produce specified heat When Gas Quality Is Bad pilot will not stay lit burner s wi...

Page 17: ...616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542...

Page 18: ...18 105562 NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN FA 2B ODS PILOT 7 7 24 23 20 1 21 22 26 4 6 7 10 7 15 5 14 13 10 9 8 11 19 18 18 17 16 12 2 25 3 5 2 5 1...

Page 19: ...01 Brass Cap 1 10 L98411 01 Ignitor Line 1 11 L98054 01 Control Valve Fixed Nut 1 12 L98115 04 Main Inlet Tube Assembly 1 13 L98124 05 Valve to Regulator Gas Line Assembly 1 14 L98914 01 Pilot Regula...

Page 20: ...repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY A...

Reviews: