 WARNING: Never install the 

heater

•  in a bedroom or bathroom un-

less installed as a vented appli-

ance (see page 11)

•  in a recreational vehicle

•  where curtains, furniture, cloth-

ing or other flammable objects 

are less than 42" from the front, 

top or sides of the heater

•  in high traffic areas

•  in windy or drafty areas

 CAUTION: This heater creates 

warm air currents. These currents 

move heat to wall surfaces next 

to  heater.  Installing  heater  next 

to vinyl or cloth wall coverings or 

operating heater where impurities 

(such as, but not limited to, to-

bacco smoke, aromatic candles, 

cleaning  fluids,  oil  or  kerosene 

lamps, etc.) in the air exist, may 

discolor walls or cause odors.

IMPORTANT:

 Vent-free heaters add moisture to 

the air. Although this is beneficial, installing heater 

in rooms without enough ventilation air may cause 

mildew to form from too much moisture. See 

Air 

for Combustion and Ventilation

, page 5.

CHECK GAS TYpE

Use only the correct gas type (natural or pro-

pane/LP) for your unit. If your gas supply is not 

correct, do not install heater. Call dealer where 

you bought heater for proper type heater.

 This appliance is only for use 

with the type of gas indicated on 

the rating plate. This appliance 

is  not  convertible  for  use  with 

other gases. 

  WARNING:  This  appliance 

is equipped for natural or pro-

pane/LP  gas.  Field  conversion 

is not permitted.

INStALLAtION

NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install  this  heater  as  your  pri-

mary heat source. If you have a 

central heating system, you may 

run system’s circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In the event of a power 

outage, you can use this heater 

as your primary heat source.

 WARNING: A qualified ser-

vice person must install heater. 

Follow all local codes.

NOTICE: State or local codes may 

only allow operation of this appli-

ance  in  a  vented  configuration. 

Check your state or local codes. 

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo-

sote, ashes and loose paint by a 

qualified chimney cleaner. Creo-

sote will ignite if highly heated. A 

dirty chimney flue may create and 

distribute soot within the house. 

Inspect chimney flue and firebox 

for  damage.  If  damaged,  repair 

flue before operating heater.

  WARNING:  Seal  any  fresh 

air vents or ash clean-out doors 

located on floor or wall of fire-

place. If not, drafting may cause 

pilot  outage  or  sooting.  Use  a 

heat-resistant  sealant.  Do  not 

seal chimney flue damper. 

f i r e - p a r t s . c o m

Summary of Contents for CSL2718N

Page 1: ...in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service mus...

Page 2: ...s for installation only in a solid fuel burning mason ry or UL127 factory built fireplaceorinalistedvent lessfireboxenclosure Itis design certified for these installations in accor dance with ANSI Z21...

Page 3: ...Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater or its controls can b...

Page 4: ...orsclosed heatbuildupinsidefire placewillcauseglasstoburst Makesurethereare no obstructions across openings of fireplace 9 This log heater is designed to be smokeless If logs ever appear to smoke turn...

Page 5: ...ace or unusually tight con struction unless provisions are provided for adequate combus tionandventilationair Readthe following instructions to insure proper fresh air for this and other fuel burning...

Page 6: ...A 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unc...

Page 7: ...n5 3 or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining un confined space When ventilating to an adjoining unconfined space you...

Page 8: ...the rating plate This appliance is not convertible for use with other gases WARNING This appliance is equipped for natural or pro pane LP gas Field conversion is not permitted Installation NOTICE Thi...

Page 9: ...16 from Side Wall Example INSTALLATION Continued NOTICE Manual control heaters may be used as a vented product If so you must always run heater with chimney flue damper open If running heater with da...

Page 10: ...ances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top of fireplace opening a hood is not required see Figure 6 INSTALL...

Page 11: ...nted heater appliance must be installed only in a solid fuel burning fireplace with a working flue and constructed of noncombustible material You may use this heater as a vented product There are thre...

Page 12: ...resistant to propane LP gas not provided electric drill with 3 16 drill bit flathead screwdriver 1 Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator Con...

Page 13: ...egulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not reduce incoming gas pres sure heater regulator damage could occur Install e...

Page 14: ...stem by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply p...

Page 15: ...ng Heater page 16 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appli ance page 17 INSTALLING Log WARNING Failuretoposition thepartsinaccordancewiththese diagrams...

Page 16: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If you op erateheaterwithdoo...

Page 17: ...olknobcoun terclockwise to desired heating level The burner should light Set control knob to any heat level between HI and LO WARNING Do not operate heaterbetweenPILOTandHIGH positions Figure 19 Contr...

Page 18: ...lot Burner Pilot Burner Thermocouple Propane LP Natural Gas BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the entrance to the burner These holes may become...

Page 19: ...clumpsof dusthave now been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also Ayellow tip on the pilot flame indicates dust and dirt in the pilot as sembly There is a small pilo...

Page 20: ...talled 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When ignitor button is pressed there is no spark at ODS pilot When ignitor b...

Page 21: ...atural or pro pane LP gas company 1 Contact local natural or pro pane LP gas company 2 Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 1 Clean burner see Cleaning and Maint...

Page 22: ...until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 8 4 Clean burner see Cleaning and Maintenance page 18...

Page 23: ...ecking Gas Connec tions page 14 1 Open window and or door for ventilation 2 Contact local natural or pro pane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 18 1 Locate and correct...

Page 24: ...ll have delayed ignition heater will not produce specified heat propane LP gas supply may be low You may feel your gas pressure is too low If so con tact your local natural or propane LP gas supplier...

Page 25: ...arts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and accessories Tool Equipment Co 5 Manila Ave Hamden CT 06514 032...

Page 26: ...desatech com 119347 01A 26 15 17 18 16 9 5 6 7 19 16 4 11 3 19 19 14 2 27 12 13 8 10 1 Illustrated Parts Breakdown Variable Manually Controlled Winchester Oak Models CSL2718N AND CSL2718P fire parts...

Page 27: ...Burner Orifice Injector 1 099056 21 Burner Orifice Injector 1 9 111124 01 Burner Retainer Spring 1 10 102963 02 Burner 1 11 102568 07 Control Valve 1 102568 08 Control Valve 1 12 098508 01 Valve Retai...

Page 28: ...ualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear...

Reviews: