www.desatech.com
119347-01A
15
INStALLAtION
Continued
Equipment Shutoff Valve
Propane/LP
Supply Tank
Control Valve
Location
Figure 17 - Checking Gas Joints
(Natural Gas Only)
Gas
Meter
Equipment Shutoff Valve
Control Valve Location
Figure 16 - Checking Gas Joints
(Propane/LP Gas Only)
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve (see Figure 15,
page 14).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from gas meter (natural gas) or
propane/LP supply to equipment shutoff valve
(see Figure 16 or 17). Apply a commercial
leak detection solution to all joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light heater (see
Operating Heater
, page 16).
Check all other internal joints for leaks.
7. Turn off heater (see
To Turn Off Gas to Appli-
ance
, page 17).
INSTALLING LOG
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
CAUTION: After installa-
tion and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to High, check
to see if flames contact any log.
If so, reposition log according to
the log installation instructions
in this manual. Flames contact-
ing log will create soot.
It is very important to install this log exactly as
instructed. Do not modify log. Only use log sup-
plied with heater.
1. Place one piece log over burner so that the
back sits on back tabs and front rests on grate
fingers (see Figure 18).
2. Add lava rock around base of heater if desired.
Do not place lava rock on log or burner.
Figure 18 - Installing One Piece Log
f i r e - p a r t s . c o m