background image

11

107435

OWNER’S MANUAL

For more information, visit www.desatech.com

Figure 17 - Installing Blower Control Housing

Power
Cord

Speed Control
Housing

Control
Knob

Figure 16 - Routing Power Cord

Blower Speed
Control Housing

 WARNING: ELECTRICAL

GROUNDING INSTRUCTIONS
This appliance is equipped with a
three-prong (grounding) plug for
your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle.

101584-05

120 Vac.   60 Hz. .  78 Amps
DESA International, Bowling Green, KY

 

WARNING: Never attempt to service heater while it

is plugged in, operating, or hot. Burns and electrical
shock could result. Only a qualified service person
should service or repair heater.

If any of the original wire as supplied with the appliance must be
replaced, it must be replaced with 105

°

C wire or it’s equivalent.

 WARNING: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause im-
proper and dangerous operation. Verify proper opera-
tion after servicing.

Wiring
Diagram
Decal

INSTALLATION

Continued

Variable

Fan Switch 

White

White

Black

Green

On

110/115 

V.A.C.

Blower

Motor

Black

Black

Black

Off

13. Using the four screws previously re-

moved, mount blower assembly to
stove by reattaching blower brackets to
rear panel (see Figure 15, page 10).
Tighten screws securely.

14. Install plastic control knob onto output

shaft of speed control housing (see Fig-
ure 16). Place speed control housing
just inside control compartment door
in front of stove (see Figure 17).

15. Using two screws provided in blower

kit, mount blower speed control hous-
ing to mounting tab in left side of lower
control compartment (see Figure 17).

16. Check to make sure that the power cord is

completely clear of blower wheel and there
are no foreign objects in blower wheel.

17. Carefully replace stove top panel. Align

holes and replace six screws removed
in step 1, page 10. Slide top trim onto
top panel. Attach with 2 screws re-
moved in step 1, page 10.

18. Peel off the backing paper and stick the

supplied wiring diagram decal on the
stove floor as shown in Figure 16.

19. Plug power cord into a convenient 3-prong

grounded wall receptacle near the stove.

INSTALLING OPTIONAL
BLOWER ACCESSORY
GA3650TA

Tools required: Phillips screwdriver

NOTICE: Shut off gas heater during
the following blower installation.

1.

Remove 2 screws from rear tabs on top
trim. Pull trim forward to remove  (see
Figure 12, page 10).

2.

Remove three screws from under top
lip on each side of stove to remove top
panel (see Figure 12, page 10).

3.

Facing front of stove, carefully slide top
panel forward until it is completely re-
moved from stove (see Figure 12, page
10).

6.

Install one plastic bushing provided in
blower kit into the 1 

1

/

2

" hole in the left

rear of firebox floor. Access hole
through the rectangular opening in the
rear panel (see Figure 13, page 10).

4.

Disconnect power cord wires from blower
motor (if connected) (see Figure 14, page
10).

5.

Disconnect green ground wire from
blower housing (if connected) by re-
moving screw holding wire terminal
(see Figure 14, page 10).

7.

Remove the two blower mounting
brackets from the rear panel by remov-
ing two screws each (see Figure 15,
page 10).

8.

Attach the two mounting brackets to
blower housing using four screws pro-
vided in blower kit (2 for each bracket)
(see Figure 15, page 10). Tighten
screws securely. Place blower assem-
bly temporarily on top of firebox.

9.

If screen is installed, carefully lift
slightly and pull forward to remove.

10. If logs are installed, carefully remove

and set aside.

20. Using speed control knob, turn blower

on and check for operation.

21. All remaining parts from blower kit

may be discarded.

Continued

Summary of Contents for Comfort Glow S39PT

Page 1: ...our gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration serv...

Page 2: ...ter screen in place Make sure heater screen is in place before running heater 8 To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 15 9 Before using furniture po...

Page 3: ...ater is designed for vent free opera tion State and local codes in some areas prohibit the use of vent free heaters Figure 1 Vent Free Propane LP Gas Stove UNPACKING 1 Remove top inner pack 2 Tilt car...

Page 4: ...ater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the following in structions to insure proper fres...

Page 5: ...____Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amo...

Page 6: ...ilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within...

Page 7: ...reater clearances from floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must ma...

Page 8: ...ly INSTALLATION Continued CONNECTING TO GAS SUPPLY WARNING A qualified service personmustconnectheatertogas supply Follow all local codes Installation Items Needed Beforeinstallingheater makesureyouha...

Page 9: ...y Check re connected fittings for leaks CAUTION Make sure exter nal regulator has been installed between propane LP supply and heater SeeguidelinesunderCon necting to Gas Supply page 8 Test Pressures...

Page 10: ...ools required Phillips screwdriver NOTICE Shutoffgasheaterduring the following blower installation 1 Remove 2 screws from rear tabs on top trim Pull trim forward to remove see Figure 12 2 Remove top p...

Page 11: ...rofblowerwheelandthere are no foreign objects in blower wheel 17 Carefully replace stove top panel Align holes and replace six screws removed in step 1 page 10 Slide top trim onto top panel Attach wit...

Page 12: ...s of wire harness into the hole in firebox back panel from front of firebox Pull the ends of the harness to the top of firebox near blower see Figure 20 14 Align holes in the switch cover assem bly wi...

Page 13: ...be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavi...

Page 14: ...ermo couple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Appliance seeTroubleshooting pages 16 through 18 Figure 24...

Page 15: ...reeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or home center may carry compressed air in a can You can use a vac...

Page 16: ...ntrol valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is l...

Page 17: ...nute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clearances see pages 7 through 9 4 Clean burner see Cleaning...

Page 18: ...er produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Burner flame is excessively large and is very near or touc...

Page 19: ...t adjustment Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States...

Page 20: ...20 107435 VENT FREE PROPANE LP PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S39PT 6 5 8 4 10 3 2 1 12 13 11 10 9 7...

Page 21: ...age 24 of this manual KEY PART NO NUMBER DESCRIPTION QTY 1 107433 02 Log Set 1 2 104286 01 ODS Pilot LP 1 3 098249 01 ODS Nut 2 4 107090 02 Burner Outlet Tube 1 5 102843 01 Burner Clip 1 6 099056 17 B...

Page 22: ...107435 VENT FREE PROPANE LP PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S39PT 1 10 4 13 3 2 14 7 16 15 11 18 20 5 6 9 8 17 12 23 21 19 19 26 26 22 22 21 25...

Page 23: ...Bottom 1 14 107093 01 Brass Trim Firebox 1 15 105576 01 Knob 1 16 101386 02 Door Hinge 2 17 099230 02 Shoulder Screw 4 18 107079 01CJ Heat Deflector 1 19 102455 12 Louver Small 2 20 102455 13 Louver L...

Page 24: ...t s call DESA International s Parts Department at 1 800 972 7879 for referral information WhencallingDESAInternational haveready model number of your heater the replacement part number ACCESSORIES Pur...

Page 25: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Page 26: ...ts caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE F...