Lower
Shell

Hot Air
Outlet

Fan Guard

Fuel
Tank

Flame-out
Control Reset
Button

Side Cover

Fuel Cap

Figure 1 - 200,000 Btu/Hr

Upper Shell

Power Cord

Summary of Contents for ARL B200

Page 1: ...ANUAL 200 000 Btu Hr Models B200 R200 and REM200 ARL LOGO G 004 IMPORTANT Read and understand this manual before assembling starting or servicing heater Improper use of heater can cause serious injury Keep this manual for future reference ...

Page 2: ...bon Monoxide Poisoning Early signs of carbon monoxide poisoning re semble the flu with headaches dizziness and or nausea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people are more affected by carbon monoxide than others These include preg nant women persons with heart or lung diseaseoranemia thoseundertheinfluence of alcohol and t...

Page 3: ...items from carton 3 Check items for shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT IDENTIFICATION UNPACKING Lower Shell Hot Air Outlet Fan Guard Fuel Tank Flame out Control Reset Button Side Cover Fuel Cap Figure 1 200 000 Btu Hr Upper Shell Power Cord ...

Page 4: ...nd Handle Assembly 2 Place cap nuts on axle ends Gently tap with hammer to secure 3 Place heater on wheel support frame Make sure air inlet end rear of heater is over wheels Line up holes on fuel tank flange with holes on wheel sup port frame 4 Place front handle and rear handle if provided on top of fuel tank flange Insert screws through handle s fuel tank flange and wheel support frame Attach nu...

Page 5: ...r Head Motor Fan Electronic Ignitor Air Line To Burner Air Pump OPERATION TO STOP HEATER 1 Unplug extension cord from outlet TO RESTART HEATER 1 Wait two minutes after stopping heater 2 Repeat steps under To Start Heater WARNING Review and un derstand the warnings in the Safety Information section page 2 They are needed to safely op erate this heater Follow all local codes when using this heater T...

Page 6: ...ARNING Never service heater while it is plugged in op erating or hot Severe burns and electrical shock can occur STORING TRANSPORTING OR SHIPPING Note If shipping transport companies re quire fuel tanks to be empty 1 Drain fuel tank Note This model has a drain plug on underside of fuel tank Remove drain plug to drain all fuel Be sure all fuel is removed 2 Replace drain plug 3 If any debris is note...

Page 7: ...p position or carbon deposits across gap 3 Dirty fuel filter 4 Dirt in nozzle 5 Water in fuel tank 6 Bad fuel valve 1 See Pump Pressure Adjustment page 8 2 See Spark Plug page 10 3 See Fuel Filter page 9 4 See Nozzle page 10 5 Drain and flush fuel tank with clean kerosene See Storing Transporting or Shipping page 6 6 See Fuel Valve page 9 WARNING Highvoltage Motor does not start when heater is plu...

Page 8: ...le it is plugged in op erating or hot Severe burns and electrical shock can occur Upper Shell Fan Guard Figure 7 Air Output Air Intake and Lint Filters AIR OUTPUT AIR INTAKE AND LINT FILTERS 1 Remove upper shell see Upper Shell Removal 2 Remove filter end cover screws using 5 16 nut driver 3 Remove filter end cover 4 Replace air output and lint filters 5 Wash or replace air intake filter see Preve...

Page 9: ...de Cover Bushing Lower Fuel Line and Fuel Filter Figure 10 Fuel Filter Removal Fuel Valve Fitting Figure 11 Fuel Valve Replacement Lower Fuel Line Electrical Wires Fuel Valve Valve Fittings Bracket Screw Screw 4 Disconnect red and white wires from fuel valve see Figure 11 5 Using 1 4 nut driver remove 2 screws lockwashers holding fuel valve and bracket to lower shell see Figure 11 Save these screw...

Page 10: ...ark plug wire to spark plug 8 Replace fan see Fan page 8 9 Replace fan guard and upper shell see Upper Shell Removal page 8 Figure 13 Spark Plug Gap Figure 12 Spark Plug Removal Figure 14 Acceptable Range For Side Electrode SERVICE PROCEDURES Continued Spark Plug Wire Spark Plug Burner Head Wave Spring Washer Gap Bend Here to Adjust Gap 270 ACCEPTABLE RANGE FOR SIDE ELECTRODE Side Electrode Figure...

Page 11: ... compressed air 8 Install insert and rotor 9 Checkgaponrotor Adjustto 003 004 if needed see Figure 18 Note Rotaterotoronefullturntoinsurethe gap is 003 004 at tightest position Ad just if needed 10 Install blades pump plate air filters and filter end cover 11 Replace fan guard and upper shell 12 Adjust pump pressure see Pump Pres sure Adjustment page 8 Note If rotor is still binding proceed as fol...

Page 12: ...er Head Assembly 7 7 7 3 7 4 7 5 7 6 10 16 10 17 10 15 10 18 10 14 10 13 10 12 10 11 10 10 10 9 10 8 10 7 10 6 10 5 10 4 10 3 10 2 10 1 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 22 21 30 31 41 33 34 35 36 23 14 13 40 39 17 18 32 37 38 43 42 46 47 44 44 4 44 4 44 3 44 5 44 2 44 1 Fuel Valve Assembly 44 7 44 8 44 6 ...

Page 13: ...placeable parts used in your heater When ordering parts be sure to provide the correct model and serial numbers from the model plate then the part number and description of the desired part KEY PART NO NUMBER DESCRIPTION QTY See OPTIONAL ACCESSORIES Not available as an assembly 20 M51150 01 Fuel Filter 1 21 M51345 04 Fuel Line Tube 1 22 M10990 3 Rubber Bushing 1 23 M50814 03 Airline 1 24 098511 21...

Page 14: ...PART NUMBER DESCRIPTION QTY M9900 192 Combustion Chamber Grounding Wire 1 098493 01 General Information Decal 1 PARTS LIST Continued 5 7 6 TECHNICAL SERVICE Output Rating Btu Hr 200 000 Fuel Use Only Kerosene or No 1 Fuel Oil Fuel Tank Capacity U S Gal 13 5 Fuel Consumption Gal Per Hr 1 4 Pump Pressure PSI 6 0 Electric Requirements 120 V 60 Hz Amperage Normal Run 4 5 Hot Air Output CFM 600 Motor R...

Page 15: ...ive part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they cannot supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready model number of your heater the replacement part number REPLACEMENT PARTS Purchase accessories and parts from your nearest dealer...

Page 16: ...retail purchaser when proof of purchase is provided This warranty covers only the cost of parts and labor required to restore the product to proper operating condition Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty Warranty service is available only through authorized dealers and service centers Thiswarrantydoesnotcoverdefectsresulting...