OBSERVED PROBLEM

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Moisture/condensation noticed on windows

Heater produces a whistling noise when
burner is lit

Dark residue on logs or inside of fireplace

White powder residue forming within burner
box or on adjacent walls or furniture

Remote does not function

REMEDY

1. Contact local propane/LP or natural gas

company

2. Clean burner (see Cleaning and Main-

tenance, pages 16 and 17) or replace
burner orifice

1. Clean burner (see Cleaning and Main-

tenance, pages 16 and 17) or replace
burner orifice

2. Replace damaged burner
3. Replace gas control

1. Check burner for dirt and debris. If

found, clean burner (see Cleaning and
Maintenance
, pages 16 and 17)

2. Replace gas control
3. Problem will stop after a few hours of

operation

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local pro-
pane/LP or natural gas company

3. Observe minimum installation clear-

ances (see page 7)

4. Clean burner (see Cleaning and Main-

tenance, pages 16 and 17) or replace
burner orifice

1. Properly locate logs (see Installing Gas

Log Heater Into Stove, page 10 )

2. Eliminate source of drafts around heater

3. Clean out air holes at burner inlet. Peri-

odically repeat as needed

4. Remove blockage or replace burner

1. Turn heater off when using furniture

polish, wax, carpet cleaners, or similar
products

1. Replace 9-volt batteries in receiver and

hand-held remote control

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Manifold pressure is too low

2. Burner orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing processes

and logs curing

1. Not enough combustion/ventilation air

1. Turning control knob to HI position

when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1. Improper log placement

2. Drafts or other air currents affecting

flame pattern

3. Air holes at burner inlet blocked

4. Burner flame holes blocked

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. may turn
into white powder residue

1. Battery is not installed. Battery power

is low

TROUBLESHOOTING

Summary of Contents for Amity

Page 1: ...ualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injuryorpropertydamage Refertothismanual for correct installa...

Page 2: ...g WARNING Anychangetothisheateroritscontrols can be dangerous WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create dr...

Page 3: ...ater needs fresh outside air ventilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Ai...

Page 4: ...ually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide a...

Page 5: ...the outdoors Example Gas water heater _____________ Btu Hr Vent free heater _____________ Btu Hr Total _____________ Btu Hr WARNING If the area in which the heater may be operated is smaller than tha...

Page 6: ...Code ANSI Z223 1 NFPA 5 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic ha...

Page 7: ...clearances If you can provide greater clearances from floor ceil ing and adjoining side and back walls Carefully follow the instructions below This stove is a freestanding unit designed to set directl...

Page 8: ...from inside stove cavity Contents include 1 Stove bottom 4 Legs Amity and Victor Hearth models include leg leveler bolts 1 Bottom door 1 Top grate 1 Hardware kit bag with fasteners 6 Carefully lay sto...

Page 9: ...er stove is in normal standing position 13 Carefully lift stove back up on its four attached legs 14 Set top grate into stove top 15 If available install gas log heater inside stove cavity before inst...

Page 10: ...se mounting hole and through stove bottom Connect hex nut to bolt on underside of stove bottom The bolt hex head is for a 5 16 socket and the hex nuts are for a 3 8 socket If sockets are not available...

Page 11: ...r connect propane LP heater di rectly to the propane LP supply This heater requires anexternalregulator notsupplied Installtheexternal regulator between the heater and propane LP supply WARNING This a...

Page 12: ...leaks after installing or servicing Correct all leaks at once CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance wit...

Page 13: ...ly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not...

Page 14: ...e away from home for long periods of time Heater will come on automatically with selector switch in the ON position OPERATING HEATER Continued O F F P I L O T O N L O IH AUTO OFF ON Figure 23 Control...

Page 15: ...fullypress the C F mode button with the end of a paper clip or similar blunt object Manual Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote control 2 Press the MANU but...

Page 16: ...njector Holder and Pilot Air Inlet Hole Figure 30 Injector Holder On Outlet Burner Tube Burner Tube Injector Holder Primary Air Inlet Holes CLEANING AND MAINTENANCE WARNING Turn off heater and let coo...

Page 17: ...cated at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector hold...

Page 18: ...onnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pilot assembly 6 Replace pilot assembly 1 T...

Page 19: ...pane LP or natural gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Main tenance pages 16 and 17 or replace burner orifice 1 Properly locate logs see I...

Page 20: ...g noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1...

Page 21: ...h com REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this prod...

Page 22: ...isit www desatech com ILLUSTRATED PARTS BREAKDOWN MODELS SVYD18PR AND SVYD18NR O F F P I L O T O N H I L O H I L O O F F P I L O T O N 17 17 18 19 24 15 14 16 13 12 12 11 22 23 20 10 9 21 4 8 5 3 2 21...

Page 23: ...7 15 Pilot Tube 1 10 103781 02 103781 01 Gas Control Valve 1 11 103345 02 103345 02 Lower Bracket 1 12 M11084 38 M11084 38 Screw 8 x 38 7 13 104383 02CK 104383 02CK Painted Base Assy 1 14 098271 10 09...

Page 24: ...esatech com ILLUSTRATED PARTS BREAKDOWN AMITY SCIVF SERIES PSCIVF SERIES VICTOR HEARTH VH SERIES Indicates Color Suffix Designation ILLUSTRATED PARTS BREAKDOWN SCIVF PSCIVF and VH Series Stove Bodies...

Page 25: ...44 One Leg Porcelain Enamel Black 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55mm Long 4 Total Per Stove 1 7 104177 01 Hardware Kit 1 7 1 Door Hinge Step Bolt With Shoulder 1 Per Unit...

Page 26: ...ote control WALL MOUNT THERMOSTAT SWITCH GWMT1 Not Shown For remote ready models The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pil...

Page 27: ...ed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 4...

Page 28: ...111162 01B 28 For more information visit www desatech com For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 29: ...___________________________________________________________ _______________________________________________________________________________________________ ____________________________________________...

Page 30: ...ation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJU...

Reviews: