background image

30/35/40,000 Btu/Hr Heater

PrOPaNe CONStruCtION FOrCeD aIr Heater

OWNer’S MaNuaL

IMPORTANT: Read and understand this manual before 
assembling, starting or servicing heater. Improper use 
of heater can cause serious injury. Keep this manual for 
future reference.

 

GENERAL HAZARD WARNING:

Failure to comply with the precautions and instructions 
provided  with  this  heater,  can  result  in  death,  serious 
bodily injury and property loss or damage from hazards 

of fire, explosion, burn, asphyxiation, carbon monoxide 

poisoning and/or electrical shock.
Only persons who can understand and follow the instruc-
tions should use or service this heater.
If you need assistance or heater information such as an in-
structions manual, labels, etc. contact the manufacturer.

taBLe OF CONteNtS

Safety .................................................................. 2
Unpacking............................................................ 3
Product Identification ........................................... 3
Theory of Operation............................................. 4
Propane Supply ................................................... 4
Installation ........................................................... 4
Ventilation ............................................................ 5
Operation ............................................................. 5
Storage ................................................................ 6

Maintenance ........................................................ 7
Service Procedures ............................................. 7
Specifications ...................................................... 9
Troubleshooting ................................................. 10
Accessories ........................................................11
Technical Services ..............................................11
Replacement Parts .............................................11
Parts .................................................................. 12
Warranty ............................................................ 14

Save this manual for future reference.

Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com

Summary of Contents for 35-FAC

Page 1: ...iation carbon monoxide poisoning and or electrical shock Onlypersonswhocanunderstandandfollowtheinstruc tions should use or service this heater Ifyouneedassistanceorheaterinformationsuchasanin structi...

Page 2: ...por withdrawal 8 Provide adequate ventilation Before using heater provide at least a 1 5 ft2 1400 cm2 opening of fresh outside air 9 For indoor use only Do not use heater outdoors 10 Do not use heater...

Page 3: ...hot or operating 20 Not intended for use on finished floors 21 Never block air inlet rear or air outlet front of heater 22 Keep heater away from strong drafts water spray rain or dripping water 23 Do...

Page 4: ...ready for use from propane tanks varies Two factors decide this amount 1 The amount of propane gas in tank s 2 The temperature of tank s This heater is designed to operate with a minimum 20 b 9 kg pro...

Page 5: ...owly excess flow check valve on propane tank will stop gas flow You may hear a click from the excess flow check valve closing If this happens reset the excess flow check valve by closing propane suppl...

Page 6: ...p NOTICE Ifheaterisunpluggedor poweroutageoccurswhileheater isrunning thethermallimitdevice will stop fuel flow Afew seconds occur before the thermal limit de vice activates During this short time fla...

Page 7: ...dusty clean heater with a damp cloth Use household cleaners on difficult spots 2 Inspect heater before each use Check connections for leaks Apply mixture of liquid soap and water to connections Bubble...

Page 8: ...shell 2 Remove motor and fan guard from heater shell see Figure 6 page 7 3 Use hex wrench to loosen set screw that holds fan to motor shaft see Figure 7 page 7 4 Remove fan Be careful not to damage t...

Page 9: ...6 Ignition Manual Piezo Temperature Range for Heater Operation 0 F to 85 F 17 C to 29 4 C 35 000 Btu Models 35 000 BTU Hr Output Rating Fuel Propane Vapor Fuel Consumption Hour 0 38 gal 1 44 liter 1 6...

Page 10: ...above 85 F 29 44 C Run heater in cooler tempera tures 2 Check heater inlet and out let Remove any obstruc tions 3 Replace fan See Fan page 8 4 Clean heater See Mainte nance page 7 OBSERVED FAULT Fand...

Page 11: ...or parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling D...

Page 12: ...F 12 Parts Models RLP30A REM30LPA 35 fac rllp35a spc 35 RLP40 spc 40A and BLP42A 3 12 13 16 14 15 8 6 7 9 5 11 10 1 2 5 17 4 Available from Allparts Equipment and Accessories 1 877 475 5660 www allpar...

Page 13: ...Clip 2 11 121216 01 Handle 1 12 113851 01 Fan 1 13 113849 01 Motor Assembly 1 14 113850 01 Fan Guard 1 15 113865 01 Bushing Strain Relief 1 16 098219 25 Cord Power Supply 1 17 114168 01 Burner Assemb...

Page 14: ...per operating condition and an allowance for labor when provided by a DESA Heating LLC Authorized Service Center or a provider approved by DESA Heating LLC Warranty parts must be obtained through auth...